IEC Manual Motor Starters
Overview.........................................................................................................6-2 Selection Guide............................................................................................6-5 Accessories – Front Mounted ...............................................................6-7 Accessories – Side Mounted .................................................................6-7 Accessories – Group Mounted .............................................................6-9 Accessories – External Handle Operators ...................................6-10 Accessories – Other................................................................................6-10 Accessories – Integrated Starter Components .........................6-11 Enclosures and Enclosure Accessories .........................................6-13 Integrated with Contactor, Open, AC Operated Contactors, Standard Interruption Capacity ...........................6-15 Integrated with Contactor, Open, DC Operated Contactors, Standard Interruption Capacity ...........................6-16 Integrated with Contactor, Open, AC Operated Contactors, High Interruption Capacity.....................................6-17 Integrated with Contactor, Open, DC Operated Contactors, High Interruption Capacity.....................................6-18 Integrated with Contactor, Factory Installed Accessories..............................................................................................6-19
Rev. 4/16 Prices and data subject to change without notice
www.geindustrial.com
Section 6
Enclosed, Non-metal Enclosures, Standard Interruption Capacity.....................................................6-20 Enclosed, Factory Installed Accessories .......................................6-21 Enclosed, Metal Enclosures, High Interruption Capacity ......6-22 Enclosed, Factory Installed Accessories .......................................6-23 Integrated with Contactor, Enclosed, AC Operated Contactors, High Interruption Capacity ........6-24 Integrated with Contactor, Enclosed, DC Operated Contactors, High Interruption Capacity ........6-26 Integrated with Contactors, Factory Installed Accessories .........................................................6-28 Outline Drawings .....................................................................................6-30 Wiring Diagrams – Accessories ........................................................6-42 Short Circuit Current Rating, Rating Breaking Capacity .......6-44 Type 2 Short Circuit Rating, Individual Group and Combination Starters..........................................................................6-45 Specifications.............................................................................................6-46 Time Current Curves...............................................................................6-47
Control Catalog
6-1
IEC Manual Motor Starters
Section 6
Overview GE’s Surion IEC motor starters are compact and reliable. They are flexible, quick in installation and available in 45mm and 55mm widths. The GPS1 line spans current ranges from 0.1A to 32A for use with motors up to 30hp at 600V. The GPS2 series extends this current range to 63A for use with motors up to and including 50 hp. Surion GPS1 starters are available in two versions. The GPS1BS_ _ series, with a toggle operator, is suitable for individual and group installations. Short circuit interruption capacity ranges up to 100kA @ 240V, 50kA @ 480V and 10kA @ 600V for individual installations and 100 kA @ 240V, 65kA @ 480V and 25kA @ 600V for group installations. The GPS1BH_ _ series, with a rotary operator, carries equivalent or higher short circuit ratings and is also suitable for combination installations with a short circuit interruption rating of 50kA for 277/480V and below. The GPS2BH_ _ series also features a rotary operator and is suitable for all three types of installations. Complete short circuit ratings are listed on page 6-44. All Surion IEC motor starters include the following features: —45mm width up to 32 amps, 55mm width rated to 63 amps —Three position operator: OFF-TRIP-ON —Padlockable in the OFF position —Class 10 overload trip characteristics —Ambient compensated –20°C to +60°C —Single-phase sensitivity —Anti tamper cover over current adjustment dial —Trip test —Complete range of common accessories —Finger-safe terminals —Pz 2 slotted/combination screws —35mm DIN rail mounting
45 mm Standard Interruption Capacity
55 mm High Interruption Capacity
Surion is global. It is available around the world in the same form, with the same product number, with both IEC and US markings, making international applications simple and sure. Surion starters are flexible in application. They not only comply with the IEC installation requirements, such as Disconnects, Main Switch, Emergency Off and Maintenance Service Switch, they may also be used in a wide variety of US applications. Surion starters may be used as —Manual starters —Group installed starters —Combination starter – manual self-protected (Type E) GPS1BH* and GPS2BH* versions —Combination starter – with C-2000 contactor or mini-contactor
Integrated With Contactor
A complete range of accessories extends the application flexibility of the line. Front and side mounted auxiliary contacts, alarm contacts, short circuit reset/indicator alarm, shunt trip and undervoltage release (with or without early make auxiliary contacts) allow Surion to easily adapt to your specific needs. Input busbars further speed and simplify group installations. Enclosures and accessories extend flexibility. Bases, links and other components allow you to assemble integrated starters.
Accessories
6-2
Control Catalog
www.geindustrial.com
Rev. 4/16 Prices and data subject to change without notice
IEC Manual Motor Starters
Section 6
Overview Individual Installation
Group Installation
Manual motor starters (UL-508, Part III) are devices that provide a means of controlling (switching on and off) a motor. UL-508 allows a manual motor starter to be applied in individual installations between a branch short circuit protection device (circuit breaker or fuse) and a motor (see Figure 1A).
Manual motor starters may be applied in group applications per Article 430-53 of the National Electrical Code. Refer to the NEC for specific requirements. Group installations are used when multiple loads are tapped off of a single branch short circuit protective device (circuit breaker or fuse). A manual motor starter is placed between the branch disconnect and each motor (see Figure 2A).
The UL, cUL listing allows Surion starters to be utilized in installations up to 600 volts. Short circuit ratings are listed in the tables on page 6-44. GE’s type MC or CL contactors may be used in series with the motor starter for remote motor operation as shown in Figure 1B. Contactors must not be applied at ratings above their nameplate HP/current ratings.
The UL, cUL listing allows starters to be utilized in installations up to 600 volts. Short circuit ratings are listed in the tables on page 6-44. GE’s type MC or CL contactors may be used in series with the motor starter for remote motor operation (see Figure 2B). Contactors must not be applied at ratings above their nameplate HP/current ratings.
or
or
Figure 1A
Figure 2A
or or
Figure 1B
Rev. 4/16 Prices and data subject to change without notice
www.geindustrial.com
Figure 2B
Control Catalog
6-3
IEC Manual Motor Starters
Section 6
Overview Combination Starters Surion GPS1BH* and GPS2BH* Manual Motor Starters may be used as combination starters (UL508 Part IV) and have been evaluated by UL as manual self-protected combination motor starters (Type E) for applications 277/480 and below. They provide coordinated branch circuit short circuit protection consistent with Section 430-52(c) (6) of the NEC; a disconnecting means consistent with Section 430-109 (a) (5); a motor starter and coordinated motor overload protection (see Figure 3A). These starters may be used for controlling motors without additional upstream branch circuit protection. They may be used in place of branch devices in motor circuits only. When used in panels with multiple motor circuits, a main circuit disconnect is required in sight and within 50 feet for the protection of service personnel. Surion GPS1BH* and GPS2BH* Manual Self Protected Combination Starters may also be used with a contactor when a high number of operations are required or remote switching is desired. A combination motor starter (see Figure 3B) is created by linking the self-protected manual motor starter with an evaluated contactor that has been tested for the combination. All C-2000 contactors and mini-contactors are suitable for use with Surion starters which, when used in this configuration, are suitable as combination motor starters. Using bases and links (see page 6-12) combination motor starters may be easily assembled by distributors, OEM’s or end users. This integrated starter approach allows the user to service or replace the load switching means (contactor) and/or the interrupting/disconnecting means (Surion starter) should the need arise.
Figure 3A
For combination starter installations, the standards require a means to differentiate between a short circuit and overload trip conditions. Surion delivers this means through the use of the Short Circuit Alarm Accessory GPAE11LLA (sold separately – see page 6-7). This accessory provides specific indication of a short circuit trip condition and includes a manual reset. Add GPAPT1E terminal cover to GPS1BH* for Type E and combination starter applications. Figure 3B
6-4
Control Catalog
www.geindustrial.com
Rev. 4/16 Prices and data subject to change without notice
IEC Manual Motor Starters
Section 6
Selection Guide Selection and Pricing Surion comprises a complete range of compact, reliable motor starters, rated from 0.1A to 63A, in 45mm and 55mm frame widths. It represents a motor protection system for switching and protecting three-phase induction motors to 50hp at 600 volts. Surion starters are available worldwide. They are specifically designed to deliver total connectivity with GE’s other IEC motor starters and controls, and they can be combined with our MC and CL contactors to form integrated solutions. A full complement of accessories create solutions for all types of applications. You can choose from frontal auxiliary and alarm contacts, lateral auxiliary contacts, alarm/auxiliary and short circuit trip indicators, shunt trip, undervoltage release (with or without early make auxiliary contacts), enclosures, group bus bars and more. You can also select assembled versions.
45 mm Standard Interruption Capacity (Toggle)
Product Number Selection Instructions Selection of the starter depends on the actual motor full load current and service factor. For motors with service factor of 1.15 or greater, use motor full load current to select the appropriate current range. For motors with a service factor less than 1.15, multiply the normal full load current by .9 for the current setting. Single phase applications require all three overload legs to be energized for proper operation. Use separate conductor to connect terminal T2 to L3. Connect power to L1 and L2 and apply load between T1 and T3. Reference Publications Instructions:
DEH-40111
45 mm High Interruption Capacity (Rotary)
55 mm High Interruption Capacity (Rotary)
Rev. 4/16 Prices and data subject to change without notice
www.geindustrial.com
Control Catalog
6-5
IEC Manual Motor Starters
Section 6
Selection Guide 45 mm Standard Interruption Capacity (Toggle Operator) Individual or Group Installation, with or without C-2000 contactors or mini-contactors FLA Adjustment Range 0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4-6.3 6.3-10 9-13 11-16 14-20 19-25 24-32
Three Phase Horsepower @ 200-208V
1/4 1/2 3/4 1 2 3 3 5 7 1/2 10
Three Phase Horsepower @ 220-240V
1/3 1/2 3/4 1 1/2 3 3 5 5 7 1/2 10
Three Phase Horsepower @ 440-480V
1/2 3/4 1 2 3 5 7 1/2 10 10 15 20
Three Phase Horsepower @ 575-600V
1/2 3/4 1 1/2 3 5 7 1/2 10 10 15 20 30
Single Phase Horsepower @ 115V
1/8 1/4 1/2 1/2 1 1 1/2 2 2
Single Phase Horsepower @ 230V
Instantaneous Short Circuit Release Amps
Product Number
List Price GO-10A2C
1/10 1/6 1/3 1/2 1 1/2 2 2 3 3 5
2.1 3.3 5.2 8.2 13 20.8 32.5 52 81.9 130 169 208 260 325 416
GPS1BSAA GPS1BSAB GPS1BSAC GPS1BSAD GPS1BSAE GPS1BSAF GPS1BSAG GPS1BSAH GPS1BSAJ GPS1BSAK GPS1BSAL GPS1BSAM GPS1BSAN GPS1BSAP GPS1BSAR
$88.00 $88.00 $88.00 $88.00 $100.00 $100.00 $100.00 $100.00 $100.00 $100.00 $120.00 $120.00 $120.00 $135.00 $135.00
45 mm High Interruption Capacity (Rotary Operator) Individual, Group or Combination1, 2 Installation, with or without C-2000 contactors or mini-contactors FLA Adjustment Range 0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4-6.3 6.3-10 9-13 11-16 14-20 19-25 24-32
Three Phase Horsepower @ 200-208V
1/4 1/2 3/4 1 2 3 3 5 7 1/2 10
Three Phase Horsepower @ 220-240V
1/3 1/2 3/4 1 1/2 3 3 5 5 7 1/2 10
Three Phase Horsepower @ 440-480V
1/2 3/4 1 2 3 5 7 1/2 10 10 15 20
Three Phase Horsepower @ 575-600V
1/2 3/4 1 1/2 3 5 7 1/2 10 10 15 20 30
Single Phase Horsepower @ 115V
1/8 1/4 1/2 1/2 1 1 1/2 2 2
Single Phase Horsepower @ 230V
Instantaneous Short Circuit Release Amps
Product Number
List Price GO-10A2C
1/10 1/6 1/3 1/2 1 1/2 2 2 3 3 5
2.1 3.3 5.2 8.2 13 20.8 32.5 52 81.9 130 169 208 260 325 416
GPS1BHAA GPS1BHAB GPS1BHAC GPS1BHAD GPS1BHAE GPS1BHAF GPS1BHAG GPS1BHAH GPS1BHAJ GPS1BHAK GPS1BHAL GPS1BHAM GPS1BHAN GPS1BHAP GPS1BHAR
$110.00 $110.00 $110.00 $110.00 $125.00 $125.00 $125.00 $125.00 $125.00 $125.00 $150.00 $150.00 $150.00 $165.00 $165.00
55 mm High Interruption Capacity (Rotary Operator) Individual, Group or Combination2 Installation, with or without C-2000 contactors or mini-contactors FLA Adjustment Range 6.3-10 9-13 11-16 14-20 19-25 24-32 28-40 35-50 45-63
Three Phase Horsepower @ 200-208V
Three Phase Horsepower @ 220-240V
Three Phase Horsepower @ 440-480V
Three Phase Horsepower @ 575-600V
Single Phase Horsepower @ 115V
Single Phase Horsepower @ 230V
Instantaneous Short Circuit Release Amps
Product Number
List Price GO-10A2C
2 3 3 5 7 1/2 10 10 15 15
3 3 5 5 7 1/2 10 10 15 20
5 7 1/2 7 1/2 10 15 20 25 30 40
7 1/2 10 10 15 20 25 30 40 50
1/2 1/2 1 1 1/2 2 2 3 3 5
1 1/2 2 2 2 3 5 7 1/2 10 10
130 169 208 260 325 416 520 650 819
GPS2BHAK GPS2BHAL GPS2BHAM GPS2BHAN GPS2BHAP GPS2BHAR GPS2BHAS GPS2BHAT GPS2BHAU
$245.00 $245.00 $245.00 $245.00 $245.00 $245.00 $275.00 $275.00 $302.00
1When using manual starters in combination starter applications, use short circuit reset/indicator accessory. For GPS1BH_ _starters add GPAPT1E terminal accessory. 2Maximum voltage for combination control is 277/480.
Product Number Selection Instructions Selection of the starter depends on the actual motor full load current and service factor. For motors with service factor of 1.15 or greater, use motor full load current to select the appropriate current range. For motors with a service factor less than 1.15, multiply the normal full load current by .9 for the current setting. Single phase applications require all three overload legs to be energized for proper operation. Use separate conductor to connect terminal T2 to L3. Connect power to L1 and L2 and apply load between T1 and T3.
6-6
Control Catalog
www.geindustrial.com
Rev. 4/16 Prices and data subject to change without notice
IEC Manual Motor Starters
Section 6
Accessories Front Mounted (Internal) Accessories—Auxiliary and Alarm Contacts Snap away the dust cover(s) and up to two front mounted accessories slide into the starter, increasing application flexibility without increasing width. Accessory Type
For Use With
Mounting Position
Contact Configuration
Product Number
List Price GO-10A2C
Auxiliary Contact (Front Mount) Auxiliary Contact (Front Mount) Alarm Contact (Front Mount) Alarm Contact (Front Mount) Front Aux. Position Cover (Package of 10)
GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2*
Left or right front Left or right front Right front Right front
1NC 1NO 1NC 1NO
GPAC01FBA GPAC10FBA GPAL01FRA GPAL10FRA
$12.00 $12.00 $14.00 $14.00
GPS1*/GPS2*
Left or right front
N/A
GPAC0VF1A
$0.50
GPAC_ _FBA Front Mounted Auxiliary Contacts
Side Mounted Accessories—Auxiliary and Alarm Contacts Snap on accessories - maximum of [(2) auxiliary contact blocks] or [(1) auxiliary contact block plus (1) alarm/aux. block or (1) short circuit indicator] or [(1) alarm/auxiliary plus (1) short circuit indicator] left and (2) auxiliary contact blocks or (1) shunt trip or (1) undervoltage release right. Accessory Type
For Use With
Mounting Position
Contact Configuration
Product Number
List Price GO-10A2C
Auxiliary Contact (Side Mount Auxiliary Contact (Side Mount) Auxiliary Contact (Side Mount) Auxiliary Contact (Side Mount) Auxiliary Contact (Side Mount) Auxiliary Contact (Side Mount) Alarm/Auxiliary Contact (Side Mount) Alarm/Auxiliary Contact (Side Mount) Alarm/Auxiliary Contact (Side Mount) Alarm/Auxiliary Contact (Side Mount) Short Circuit Alarm (Side Mount)
GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2*
Left Left Left Right Right Right Left Left Left Left Left
2NC 1NO + 1NC 2NO 2NC 1NO + 1NC 2NO 1NC Alarm + 1NC Aux. 1NC Alarm + 1NO Aux. 1NO Alarm + 1NC Aux. 1NO Alarm + 1NO Aux. 1NO + 1NC
GPAC02LLA1 GPAC11LLA1 GPAC20LLA1 GPAC02LRA1 GPAC11LRA1 GPAC20LRA1 GPAD0101LLA GPAD0110LLA GPAD1001LLA GPAD1010LLA GPAE11LLA2
$18.00 $18.00 $18.00 $18.00 $18.00 $18.00 $24.00 $24.00 $24.00 $24.00 $15.00
GPAC_ _FRA Front Mounted Alarm Contacts
1GPS1BSAR and GPS1BHAR (24-32 FLA starters) can accept all accessory combinations noted above except that
only one lateral auxiliary contact block may be used on this size. 2GPAE11LLA short circuit alarm may not be used with non-metallic enclosures due to reset button interference.
GPAC_ _LLA/GPAC_ _LRA Side Mounted Auxiliary Contacts
GPAD_ _ _ _LLA Side Mounted Alarm/Auxiliary Contact
GPAE11LLA Side Mounted Short Circuit Alarm Terminal Identification and Wiring Diagrams: See page 6-42
Rev. 4/16 Prices and data subject to change without notice
www.geindustrial.com
Control Catalog
6-7
IEC Manual Motor Starters
Section 6
Accessories Side Mounted Accessories—Shunt Trip Snap on accessories - maximum of (2) auxiliary contact blocks or (1) shunt trip or (1) undervoltage release right side. Accessory Type
For Use With
Mounting Position
Coil Voltage
Product Number
List Price GO-10A2C
Shunt Trip Shunt Trip Shunt Trip Shunt Trip Shunt Trip Shunt Trip Shunt Trip Shunt Trip Shunt Trip Shunt Trip Shunt Trip Shunt Trip
GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2*
Right Right Right Right Right Right Right Right Right Right Right Right
24V 60/50 Hz 48V 60 Hz 60V 60 Hz, 48V 50 Hz 120V 60 Hz, 110-127V 50 Hz 208V 60 Hz 240V 60 Hz, 220V 50 Hz 277V 60 Hz, 240V 50 Hz 380/400V 50 Hz 460-480V 60 Hz, 415-440V 50 Hz 600V 60 Hz, 500V 50 Hz 24-60V DC 110-240V DC
GPASLRAA1 GPASLRAAF GPASLRAAG GPASLRAAJ GPASLRAAM GPASLRAAN GPASLRAAR GPASLRAAU GPASLRAAW GPASLRAAY GPASLRADD GPASLRADJ
$48.00 $48.00 $48.00 $48.00 $48.00 $48.00 $48.00 $48.00 $48.00 $48.00 $48.00 $48.00
GPASLRA_ _Shunt Trip
De-energizes the controller when external signal is applied to shunt coil.
Side Mounted Accessories—Undervoltage Release Snap on accessories - maximum of (2) auxiliary contact blocks or (1) shunt trip or (1) undervoltage release right side. Accessory Type
For Use With
Mounting Position
Coil Voltage
Product Number
List Price GO-10A2C
Undervoltage Release Undervoltage Release Undervoltage Release Undervoltage Release Undervoltage Release Undervoltage Release Undervoltage Release Undervoltage Release Undervoltage Release Undervoltage Release Undervoltage Release
GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2* GPS1*/GPS2*
Right Right Right Right Right Right Right Right Right Right Right
24V 60 Hz 24V 50 Hz 48V 60 Hz 48V 50 Hz 120V 60Hz, 110-127V 50 Hz 208V 60 Hz 240-260V 60 Hz, 220/230V 50 Hz 277V 60 Hz, 240V 50 Hz 380/400V 50 Hz 460-480V 60 Hz, 415-440V 50 Hz 600V 60 Hz, 500V 50 Hz
GPAULRAAC GPAULRAAD GPAULRAAF GPAULRAAG GPAULRAAJ GPAULRAAM GPAULRAAN GPAULRAAR GPAULRAAU GPAULRAAW GPAULRAAY
$48.00 $48.00 $48.00 $48.00 $48.00 $48.00 $48.00 $48.00 $48.00 $48.00 $48.00
GPAULRAA_Undervoltage Release
Provides protection from low voltage conditions; requires 85-110% voltage across D1 and D2 prior to starting motor; requires reset of starter upon undervoltage condition or loss of voltage.
Side Mounted Accessories—Undervoltage Release Snap on accessories - maximum of (2) auxiliary contact blocks or (1) shunt trip or (1) undervoltage release right side. Accessory Type Undervoltage Release Undervoltage Release Undervoltage Release Undervoltage Release Undervoltage Release Undervoltage Release Undervoltage Release Undervoltage Release Undervoltage Release Undervoltage Release Undervoltage Release
For Use With
Mounting Position
Coil Voltage
GPS1BS* GPS1BS* GPS1BS* GPS1BS* GPS1BS* GPS1BS* GPS1BS* GPS1BS* GPS1BS* GPS1BS* GPS1BS*
Right Right Right Right Right Right Right Right Right Right Right
24V 60 Hz 24V 50 Hz 48V 60 Hz 48V 50 Hz 120V 60 Hz, 110-127V 50 Hz 208V 60 Hz 240-260V 60 Hz, 220/230V 50 Hz 277V 60 Hz, 240V 50 Hz 380/400V 50 Hz 460-480V 60 Hz, 415-440V 50 Hz 600V 60 Hz, 500V 50 Hz
Product Number GPAU20LTAAC GPAU20LTAAD GPAU20LTAAF GPAU20LTAAG GPAU20LTAAJ GPAU20LTAAM GPAU20LTAAN GPAU20LTAAR GPAU20LTAAU GPAU20LTAAW GPAU20LTAAY
List Price GO-10A2C $66.00 $66.00 $66.00 $66.00 $66.00 $66.00 $66.00 $66.00 $66.00 $66.00 $66.00
GPAU20LTAA_Undervoltage Release with 2NO early make contacts
With 2NO early make contacts (provides protection from low voltage conditions; early make contacts energize release coil when operator is turned to ON position and voltage is 85-110% Ve; requires reset of starter upon undervoltage condition or loss of voltage)
Side Mounted Accessories—Undervoltage Release Snap on accessories - maximum of (2) auxiliary contact blocks] or (1) shunt trip or (1) undervoltage release right side. Accessory Type Undervoltage Release Undervoltage Release Undervoltage Release Undervoltage Release Undervoltage Release Undervoltage Release Undervoltage Release Undervoltage Release Undervoltage Release Undervoltage Release Undervoltage Release
For Use With
Mounting Position
Coil Voltage
GPS1BH*/GPS2BH* GPS1BH*/GPS2BH* GPS1BH*/GPS2BH* GPS1BH*/GPS2BH* GPS1BH*/GPS2BH* GPS1BH*/GPS2BH* GPS1BH*/GPS2BH* GPS1BH*/GPS2BH* GPS1BH*/GPS2BH* GPS1BH*/GPS2BH* GPS1BH*/GPS2BH*
Right Right Right Right Right Right Right Right Right Right Right
24V 60 Hz 24V 50 Hz 48V 60 Hz 48V 50 Hz 120V 60 Hz, 110-127V 50 Hz 208V 60 Hz 240-260V 60 Hz, 220/230V 50 Hz 277V 60 Hz, 240V 50 Hz 380/400V 50 Hz 460-480V 60 Hz, 415-440V 50 Hz 600V 60 Hz, 500V 50 Hz
Product Number GPAU20LCAAC GPAU20LCAAD GPAU20LCAAF GPAU20LCAAG GPAU20LCAAJ GPAU20LCAAM GPAU20LCAAN GPAU20LCAAR GPAU20LCAAU GPAU20LCAAW GPAU20LCAAY
List Price GO-10A2C $66.00 $66.00 $66.00 $66.00 $66.00 $66.00 $66.00 $66.00 $66.00 $66.00 $66.00
GPAU20LCAA_Undervoltage Release with 2NO early make contacts
With 2NO early make contacts (provides protection from low voltage conditions; early make contacts energize release coil when operator is turned to ON position and voltage is 85-110% Ve; requires reset of starter upon undervoltage condition or loss of voltage)
6-8
Control Catalog
www.geindustrial.com
Rev. 4/16 Prices and data subject to change without notice
IEC Manual Motor Starters
Section 6
Accessories Group Mounted Starter Accessories Accessory Type
For Use With
Maximum Amps
Spacing
Input Busbar Input Busbar Input Busbar Input Busbar Input Busbar
GPS1* GPS1* GPS1* GPS1* GPS1*
63A max. 63A max. 63A max. 63A max. 63A max.
45mm 45mm 45mm 45mm 54mm
Input Busbar
GPS1*
63A max.
54mm
Input Busbar
GPS1*
63A max.
54mm
Input Busbar
GPS1*
63A max.
54mm
Input Busbar
GPS1*
63A max.
63mm
Input Busbar
GPS1*
63A max.
63mm
Input Busbar Input Busbar Input Busbar Input Busbar
GPS2* GPS2* GPS2* GPS2*
120A max. 120A max. 120A max. 120A max.
55mm 55mm 55mm 64mm
Input Busbar
GPS2*
120A max.
64mm
Input Busbar
GPS2*
120A max.
64mm
Input Busbar
GPS2*
120A max.
73mm
Input Busbar
GPS2*
120A max.
73mm
Power Input GPS1* Busbar Terminal
63A max.
Power Input GPS2* Busbar Terminal
120A max.
Terminal Covers
GPS1*
Terminal Covers
GPS2*
Product Description
Terminal No. of Type Controllers
Used with no auxiliaries Pin Used with no auxiliaries Pin Used with no auxiliaries Pin Used with no auxiliaries Pin Used with 1 aux or 1 aux Pin alarm (one 9mm auxiliary) Used with 1 aux or 1 aux Pin alarm (one 9mm auxiliary) Used with 1 aux or 1 aux Pin alarm (one 9mm auxiliary) Used with 1 aux or 1 aux Pin alarm (one 9mm auxiliary) Used with 2 aux or 1 aux+1 Fork aux/alarm or shunt or UV (two 9mm auxiliaries or one 18mm auxiliary) Used with 2 aux or 1 aux+1 Fork aux/alarm or shunt or UV (two 9mm auxiliaries or one 18mm auxiliary) Used with no auxiliaries Pin Used with no auxiliaries Pin Used with no auxiliaries Pin Used with 1 aux or 1 aux Pin alarm (one 9mm auxiliary) Used with 1 aux or 1 aux Pin alarm (one 9mm auxiliary) Used with 1 aux or 1 aux) Pin alarm (one 9mm auxiliary) Used with 2 aux or 1 aux + Pin aux/alarm or shunt or UV (two 9mm auxiliaries or one 18mm auxiliary) Used with 2 aux or 1 aux + Pin aux/alarm or shunt or UV (two 9mm auxiliaries or one 18mm auxiliary) Used with GP1B Pozidrive busbars above Wire size – AWG 10-4 Torque – 38 lbs.-in. Used with GPB2 Allen Screw busbars above Wire Size - AWG 8 - 1/0 Torque - 54 lbs. in. Slips over unused GPB1BO_ _ (45mm) or GPB1B1_ _ (54mm) pin type input busbar terminals to provide touch protection Snaps over unused GPB2B0_ _ (55mm) or GPB2B1_ _ (64mm) pin type busbar terminals to provide touch protection
Product Number
List Price GO-10A2C
2 3 4 5 2
GPB1B02A GPB1B03A GPB1B04A GPB1B05A GPB1B12A
$12.00 $16.00 $20.00 $25.00 $14.00
3
GPB1B13A
$18.00
4
GPB1B14A
$22.00
5
GPB1B15A
$27.00
2
GPB1B22A
$22.00
4
GPB1B24A
$27.00
2 3 4 2
GPB2B02A GPB2B03A GPB2B04A GPB2B12A
$32.00 $40.00 $48.00 $34.00
3
GPB2B13A
$42.00
4
GPB2B14A
$50.00
2
GPB2B22A
$34.00
4
GPB2B24A
$50.00
GPB1FA
$16.00
GPB2FA
$28.00
GPB1GA
$2.50
GPB2GA
$3.00
GPB_B_ _ _Input Busbar
GPB_FA Power Input Busbar Terminal
GPB_GA Terminal Cover
Input Busbar simplifies group installations; different forms accommodate different accessories.
Rev. 4/16 Prices and data subject to change without notice
www.geindustrial.com
Control Catalog
6-9
IEC Manual Motor Starters
Section 6
Accessories External Handle Operators Allows operation of GPS1BH_ _ and GPS2BH_ _ starters through a panel door. Shaft mounting depth inside the panel can range from 5.5” - 11.4” (139.8 - 289.8 mm) for GPS1BH_ _ and 6.3” - 12.25” (161 - 311 mm) for GPS2BH_ _. For Use With GPS1* GPS1* GPS2* GPS2*
Handle Type
Product Number
List Price GO-10A2C
Black Red/Yellow Black Red/Yellow
GPA1HAB GPA1HAR GPA2HAB GPA2HAR
$35.00 $35.00 $40.00 $40.00
GPA_HA_Handle Operator
Other Accessories Accessory Type
For Use With
Snap-in Tabs Terminal Covers Terminal Covers
GPS1* GPS2* GPS1BH*
Description
Product Number
For Screw Mounting GPS1 to panel1 GPAKS1A IP20 (package of 6) GPAPTP2A Additional protective cover required for GPAPT1E combination control. Easily suited for field installation. May not use front mounted internal accessories with cover in place. Cannot use GPB1 busbars with protective cover.
List Price GO-10A2C $.15 ea. $1.00 $12.00
1Packaged in quantities of 10.
GPAKS1A Snap-in Tabs
GPAPTP2A Terminal Covers for GPS2*
GPAPT1E Terminal Covers for GPS1BH*
6-10
Control Catalog
www.geindustrial.com
Rev. 4/16 Prices and data subject to change without notice
IEC Manual Motor Starters
Section 6
Accessories Integrated Starter Components Accessory Type
For Use With
Contactor Prefix
Coil Volts
Bases
GPS1*
Bases Bases Bases Links Links Links Links Links Links Links Links Links Links Links Links
GPS1* GPS2* GPS2* GPS1* GPS1* GPS1* GPS1* GPS1* GPS1* GPS1* GPS2* GPS2* GPS2* GPS2* GPS2*
MC0/MC1 (optional), CL00, 01, 02, 25 (optional), CL00, 01, 02, 25 CL04 CL04, CL45 CL06, CL07 MC0/MC1 CL00, CL01, CL02 CL00, CL01, CL02 CL25 CL25 CL04 CL04 CL04 CL04 CL45 CL45 CL06, CL07
AC or DC AC DC AC or DC AC or DC AC AC & DC AC DC AC DC AC DC AC DC AC DC AC
Product Number
List Price GO-10A2C
GPF1B1A
$20.00
GPF1B4A GPF2B2A GPF2B3A GPF1LMCBA GPF1L02AA GPF1L02DA GPF1L25AA GPF1L25DA GPF1L04AA GPF1L04DA GPF2L04AA GPF2L04DA GPF2L45AA GPF2L45DA GPF2L07AA
$23.00 $25.00 $30.00 $8.00 $9.00 $12.00 $9.00 $12.00 $14.00 $18.00 $14.00 $18.00 $14.00 $18.00 $25.00
Integrated Starter Components
Integrated Starter Components For integrated starter applications, rotate CL contactors 180°, coil terminals down. This permits direct access to the A1-A2 coil terminals when contactors are assembled to the manual motor starter. Then attach the plastic cover to the front of the contactor so that terminal numbering is in the correct position. Note: After 180° rotation, the built-in auxiliary contact on CL00_ _, CL01_ _, CL02_ _ and CL04_ _ will be located on the first terminal on the left side. Contactor Prefix
Built-In Aux Contacts
Product Number
List Price GO-10A2C
CL00, CL01, CL02 CL00, CL01, CL02 CL25 CL04 CL04 CL45 CL06,CL07 (AC Only)
1NO 1NC None 1NO 1NC None None
GPF10C021 GPF01C021 GPF00C251 GPF10C042 GPF01C042 GPF00C452 GPF00C082
$3.00 $3.00 $3.00 $3.00 $3.00 $3.00 $4.00
Accessory Type Covers Covers Covers Covers Covers Covers Covers
GPF_B_A Bases
1Covers accommodate a maximum of 2 front auxiliary contact blocks. 2Covers accommodate a maximum of 4 front auxiliary contact blocks.
GPF1L_ _ _ _/GPF2L_ _ _ _Links
Cover
Rotate CL contactors 180 degrees
Rev. 4/16 Prices and data subject to change without notice
www.geindustrial.com
Control Catalog
6-11
IEC Manual Motor Starters
Section 6
Accessories Integrated Starter Components Accessory Type Wiring Kits for Reversing Starters Wiring Kits for Reversing Starters Wiring Kits for Reversing Starters Wiring Kits for Reversing Starters Wiring Kits for Reversing Starters Wiring Kits for Reversing Starters
For Use With
Contactor Prefix
Coil Volts
Product Number
List Price GO-10A2C
GPS1*
MC0/MC1
AC or DC
WKMIU
$16.00
GPS1*
CL00, CL01, CL02
AC or DC
WKLI02P
$18.00
GPS1*
CL25
AC or DC
WKLI25P
$20.00
GPS1*/GPS2*
CL04
AC or DC
WKLI04P
$30.00
GPS2*
CL45
AC or DC
WKLI45P
$32.00
GPS2*
CL06, CL07
AC
CLXC41
$48.00
Integrated Starter Components Bases and base links are required for reversers using CL contactors, optional for reversers using MC contactors. Two base links are required for each pair of reverser bases. Accessory Type Base Links for Reversers
For Use With
Product Number
List Price GO-10A2C
GPS1*
GPF1CBA
$0.80 per package
Integrated Starter Components
Product number represents package of 2.
WKLI_ _Wiring Kits for Reversing Starters
Base Links for Reversers
6-12
Control Catalog
www.geindustrial.com
Rev. 4/16 Prices and data subject to change without notice
IEC Manual Motor Starters
Section 6
Enclosures and Enclosure Accessories Enclosures (Non-metallic) For Surion Toggle Operated (GPS1BSAA-GPS1BSAP) Starters to 25 Amps Enclosures will accommodate starters with 1 auxiliary or alarm contact on the left side and 1 auxiliary contact, shunt trip or undervoltage release (with or without early make contacts) on the right side. UL Listed for use with 1/2” NPT fittings. For Use With
Mounting
Enclosure Type
Product Number
List Price GO-10A2C
GPS1BSAA-AP GPS1BSAA-AP GPS1BSAA-AP GPS1BSAA-AP
Flush Panel Flush Panel Surface Surface
NEMA Type 1/IP41 NEMA Type 3R/12/IP55 NEMA Type 1/IP41 NEMA Type 3R/12/IP55
GPEF41A GPEF55A GPES41A GPES55A
$35.00 $50.00 $30.00 $45.00
GPEF_ _A/GPES_ _A Non-Metallic Enclosure
Enclosure Accessories (Non-metallic) For Use With
Enclosure Accessory Type
GPS1BSAA-GPS1BSAP
Padlocking Device
GPS1BSAA-GPS1BSAP
GPS1BSAA-GPS1BSAP GPS1BSAA-GPS1BSAP GPS1BSAA-GPS1BSAP
External Mushroom Head Push Button External Mushroom Head Push Button External Mushroom Head Push Button Conversion Kit Neutral Kit Adapter
GPS1BSAA-GPS1BSAP GPS1BSAA-GPS1BSAP GPS1BSAA-GPS1BSAP GPS1BSAA-GPS1BSAP GPS1BSAA-GPS1BSAP GPS1BSAA-GPS1BSAP GPS1BSAA-GPS1BSAP GPS1BSAA-GPS1BSAP GPS1BSAA-GPS1BSAP GPS1BSAA-GPS1BSAP GPS1BSAA-GPS1BSAP GPS1BSAA-GPS1BSAP GPS1BSAA-GPS1BSAP GPS1BSAA-GPS1BSAP GPS1BSAA-GPS1BSAP
Indicating Lights Indicating Lights Indicating Lights Indicating Lights Indicating Lights Indicating Lights Indicating Lights Indicating Lights Indicating Lights Indicating Lights Indicating Lights Indicating Lights Indicating Lights Indicating Lights Indicating Lights
GPS1BSAA-GPS1BSAP GPS1BSAA-GPS1BSAP
Product Number
List Price GO-10A2C
Accepts up to 3 padlocks with hasps of .15-.31 inches (4-8 mm) Momentary
GPEPA
$18.00
GPEPMA
$24.00
Push-to-stop/Turn-to-release
GPEPLA
$35.00
Push-to-stop/Key-to-release
GPEPKA
$85.00
Converts Type 1 to 3R/12 (IP44 to IP55) — Adapts enclosure to Type 3R/12 (IP55) to accommodate starter with undervoltage release with early make contacts Green 110-220V Green 220-240V Green 380-440V Green 480-500V Green 600V Red 110-220V Red 220-240V Red 380-440V Red 480-500V Red 600V Transparent 110-220V Transparent 220-240V Transparent 380-440V Transparent 480-500V Transparent 600V
GPECA GPENA GPEUTA
$12.00 $5.00 $6.00
GPELGAJ GPELGAN GPELGAU GPELGAX GPELGAY GPELRAJ GPELRAN GPELRAU GPELRAX GPELRAY GPELCAJ GPELCAN GPELCAU GPELCAX GPELCAY
$18.00 $18.00 $18.00 $18.00 $18.00 $18.00 $18.00 $18.00 $18.00 $18.00 $18.00 $18.00 $18.00 $18.00 $18.00
Product Description
GPEPA Padlocking Device
GPEP_ _Mushroom Head Push Button
GPECA Conversion Kit
Reference Publications Instructions for non-metallic enclosures:
DEH-40283
GPENA Neutral Kit
GPEUTA Adapter
GPEL_A_Indicating Lights
Rev. 4/16 Prices and data subject to change without notice
www.geindustrial.com
Control Catalog
6-13
IEC Manual Motor Starters
Section 6
Enclosures and Enclosure Accessories Enclosures (Metallic) For Use With
Contactor Prefix
Enclosure Type
Product Number
List Price GO-10A2C
GPS1BH_ _ GPS2BH_ _ GPS1BH_ _/GPS2BH_ _ GPS1BH_ _/GPS2BH_ _ GPS1BH_ _ GPS1BH_ _/GPS2BH_ _ GPS1BH_ _ GPS1BH_ _
— — — All except CL04 CL04 All except CL04 CL04 CL00-CL04
NEMA Type 1 NEMA Type 1 NEMA Type 3R/12 NEMA Type 1 NEMA Type 1 NEMA Type 3R/12 NEMA Type 3R/12 NEMA Type 1
GPEM1NA GPEM1NB GPEM2NC GPEM1CC1 GPEM1CD1 GPEM2CC1 GPEM2CD1 GPEM1XA1
$60.00 $75.00 $115.00 $95.00 $95.00 $140.00 $140.00 $165.00
GPS1BH_ _
CL00-CL04
NEMA Type 3R/12
GPEM2XA1
$210.00
GPS2BH_ _
CL04-CL07
NEMA Type 1
GPEM1XB1
$165.00
GPS2BH_ _
CL04-CL07
NEMA Type 3R/12
GPEM2XB1
$210.00
Application Manual Motor Starters Manual Motor Starters Manual Motor Starters Combination Starters Combination Starters Combination Starters Combination Starters Reversing Combination2 Starters and Combination2 Starters with CPT Reversing Combination2 Starters and Combination Starters with CPT Reversing Combination2 Starters and Combination2 Starters with CPT Reversing Combination2 Starters and Combination2 Starters with CPT
GPEM_ _ _Metallic Enclosure
CLXP3NL_Pilot Light , Red & Green Lenses
1Bases are required for enclosed combination starters. 2Maximum voltage 277/480
Enclosure Pilot Devices (Metallic) For Use With
Applications
Product Description Pilot Light, Red & Green Lenses 115V Pilot Light, Red & Green Lenses 240V Pilot Light, Red & Green Lenses 277V Pilot Light, Red & Green Lenses 480V Pilot Light, Red & Green Lenses 600V Pilot Light, Red & Green Lenses 24V White Lens START-STOP Push Buttons
GPS1BH_ _/GPS2BH_ _
All Starters All Starters All Starters All Starters All Starters All Starters All Starters Non-reversing Combination Starters Non-reversing Combination Starters Non-reversing Combination Starters Reversing Combination
GPS1BH_ _/GPS2BH_ _
Reversing Combination
GPS1BH_ _/GPS2BH_ _ GPS1BH_ _/GPS2BH_ _ GPS1BH_ _/GPS2BH_ _ GPS1BH_ _/GPS2BH_ _ GPS1BH_ _/GPS2BH_ _ GPS1BH_ _/GPS2BH_ _ GPS1BH_ _/GPS2BH_ _ GPS1BH_ _/GPS2BH_ _ GPS1BH_ _/GPS2BH_ _ GPS1BH_ _/GPS2BH_ _
Product Number CLXP3NL1 CLXP3NL3 CLXP3NL7 CLXP3NL4 CLXP3NL5 CLXP3NL2 P9ASGLDB1 CLXP1NC
List Price GO-10C2 $65.00 $65.00 $65.00 $65.00 $65.00 $65.00 $1.001
CLXP1NC START-STOP Push Buttons
$65.00 START-STOP Mushroom Head Push Button H-O-A Selector Switch FORWARD-OFF-REVERSE Selector Switch FORWARD-OFF-REVERSE Push Buttons
CLXP4NC CLXP2NC
$65.00 $50.00
CLXP1RC
$50.00
CLXP3RC
$75.00
CLXP4NC START-STOP Mushroom Head Push Buttons
1List Price GO-10GC
Reference Publications Instructions for metallic enclosures: Manual motor starters: Combination starters: Reversing combination starters or combination starters with CPT:
DEH-40389 DEH-40387 DEH-40388
CLXP2NC H-O-A Selector Switch
CLXP1RC FORWARD-OFF-REVERSE Selector Switch
CLXP3RC FORWARD-OFF-REVERSE Push Buttons
6-14
Control Catalog
www.geindustrial.com
Rev. 4/16 Prices and data subject to change without notice
IEC Manual Motor Starters
Section 6
Integrated with Contactor Open, AC Operated Contactors Standard Interruption Capacity Product Number Structure for Modifications Select product from table below. See page 6-19 for starter and contactor modifications. Product Number Digits 1 G
2 P
3 2
4 3
5 N
6 A Starter Modifications
7 2
8 5
9 * (Coil)
10 A Contactor Modifications
Product Number Selection Instructions Selection of the starter depends on the actual motor full load current and service factor. For motors with service factor of 1.15 or greater, use motor full load current to select the appropriate current range. For motors with a service factor less than 1.15, multiply the normal full load current by .9 for the current setting. Single phase applications require all three overload legs to be energized for proper operation. Use separate conductor to connect terminal T2 to L3. Connect power to L1 and L2 and apply load between T1 and T3.
45 mm Standard Interruption Capacity (Toggle Operator) Integrated with Mini Contactor
45 mm (Toggle Operator) Individual or Group Installation Manual Starter Type GPS1BS_ _ FLA Adjustment Range 0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4.0-6.3 6.3-10 0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4.0-6.3 6.3-10 9-13 11-16 14-20 19-25 24-32
Three Phase Horsepower @ 200V
Three Phase Horsepower @ 230V
Three Phase Horsepower @ 460V
Three Phase Horsepower @ 575V
1/4 1/2 3/4 1 2
1/3 1/2 3/4 1 1/2 3
1/2 3/4 1 2 3 5
1/2 3/4 1 1/2 3 5 5
1/4 1/2 3/4 1 2 3 3 5 7 1/2 0
1/3 1/2 3/4 1 1/2 3 3 5 5 7 1/2 10
1/2 3/4 1 2 3 5 7 1/2 10 10 15 20
1/2 3/4 1 1/2 3 5 7 1/2 10 10 15 20 25
Single Phase Horsepower @ 115V
Single Phase Horsepower @ 230V
1/8 1/4 1/2
1/10 1/6 1/3 1/2 1 1/2
1/8 1/4 1/2 1/2 1 1 1/2 1 1/2 2
1/10 1/6 1/3 1/2 1 1/2 2 2 3 3 5
Contactor Size MC1 MC1 MC1 MC1 MC1 MC1 MC1 MC1 MC1 MC1 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL01 CL02 CL25 CL04 CL04
Contactor Max Base Amps Included 9 9 9 9 9 9 9 9 9 9 10 10 10 10 10 10 10 10 10 10 13.8 17.5 22 32 32
No No No No No No No No No No No No No No No No No No No No No No No Yes Yes
Product Number1
List Price GO-10A2A
GP23AAM1*A GP23BAM1*A GP23CAM1*A GP23DAM1*A GP23EAM1*A GP23FAM1*A GP23GAM1*A GP23HAM1*A GP23JAM1*A GP23KAM1*A GP23AA00*A GP23BA00*A GP23CA00*A GP23DA00*A GP23EA00*A GP23FA00*A GP23GA00*A GP23HA00*A GP23JA00*A GP23KA00*A GP23LA01*A GP23MA02*A GP23NA25*A2 GP23PA04*A GP23RA04*A
$198.00 $198.00 $198.00 $198.00 $210.00 $210.00 $210.00 $210.00 $210.00 $210.00 $240.00 $240.00 $240.00 $240.00 $252.00 $252.00 $252.00 $252.00 $252.00 $252.00 $295.00 $310.00 $324.00 $394.00 $394.00
1Complete product number by replacing asterisk (*) with appropriate coil digit from table below. 21NO aux contact front mounted.
Includes 1N0 auxiliary contact integrated into MC* and CL* unless noted. Integrated contact is on left side on CL* contactors.
Replace asterisk (*) in product number with coil digit. Coil Selection 60Hz 50Hz Coil Digit * for MC Contactors Coil Digit * for CL Contactors
Rev. 4/16 Prices and data subject to change without notice
24 — C —
24 24 — 1
www.geindustrial.com
120 110 J J
208 — M L
240 — — S
AC Voltage 240-277 277 — 220-230 N — — N
— 380 U —
480 380/400 — U
Control Catalog
— 415 — W
480 415 W —
600 500 Y Y
6-15
IEC Manual Motor Starters
Section 6
Integrated with Contactor Open, DC Operated Contactors Standard Interruption Capacity Product Number Structure for Modifications Select product from table below. See page 6-19 for starter and contactor modifications. Product Number Digits 1 G
2 P
3 3
4 3
5 N
6 A Starter Modifications
7 2
8 5
9 # (Coil)
10 A Contactor Modifications
Product Number Selection Instructions Selection of the starter depends on the actual motor full load current and service factor. For motors with service factor of 1.15 or greater, use motor full load current to select the appropriate current range. For motors with a service factor less than 1.15, multiply the normal full load current by .9 for the current setting. Single phase applications require all three overload legs to be energized for proper operation. Use separate conductor to connect terminal T2 to L3. Connect power to L1 and L2 and apply load between T1 and T3.
45 mm Standard Interruption Capacity (Toggle Operator) Integrated with DC Mini Contactor
45 mm (Toggle Operator) Individual or Group Installation Manual Motor Starter Type GPS1BH_ _ FLA Adjustment Range 0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4.0-6.3 6.3-10 0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4.0-6.3 6.3-10 9-13 11-16 14-20 19-25 24-32
Three Phase Horsepower @ 200V
Three Phase Horsepower @ 230V
Three Phase Horsepower @ 460V
Three Phase Horsepower @ 575V
1/4 1/2 3/4 1 2
1/3 1/2 3/4 1 1/2 3
1/2 3/4 1 2 3 5
1/2 3/4 1 1/2 3 5 5
1/4 1/2 3/4 1 2 3 3 5 7 1/2 0
1/3 1/2 3/4 1 1/2 3 3 5 5 7 1/2 10
1/2 3/4 1 2 3 5 7 1/2 10 10 15 20
1/2 3/4 1 1/2 3 5 7 1/2 10 10 15 20 25
Single Phase Horsepower @ 115V
Single Phase Horsepower @ 230V
1/8 1/4 1/2
1/10 1/6 1/3 1/2 1 1/2
1/8 1/4 1/2 1/2 1 1 1/2 1 1/2 2
1/10 1/6 1/3 1/2 1 1/2 2 2 3 3 5
Contactor Size MC1 MC1 MC1 MC1 MC1 MC1 MC1 MC1 MC1 MC1 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL01 CL02 CL25 CL04 CL04
Contactor Max Base Amps Included 9 9 9 9 9 9 9 9 9 9 10 10 10 10 10 10 10 10 10 10 13.8 17.5 22 32 32
No No No No No No No No No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Product Number1 GP33AAM1#A GP33BAM1#A GP33CAM1#A GP33DAM1#A GP33EAM1#A GP33FAM1#A GP33GAM1#A GP33HAM1#A GP33JAM1#A GP33KAM1#A GP33AA00#A GP33BA00#A GP33CA00#A GP33DA00#A GP33EA00#A GP33FA00#A GP33GA00#A GP33HA00#A GP33JA00#A GP33KA00#A GP33LA01#A GP33MA02#A GP33NA25#A2 GP33PA04#A GP33RA04#A
List Price GO-10A2A $208.00 $208.00 $208.00 $208.00 $220.00 $220.00 $220.00 $220.00 $220.00 $220.00 $293.00 $293.00 $293.00 $293.00 $305.00 $305.00 $305.00 $305.00 $305.00 $305.00 $349.00 $363.00 $382.00 $437.00 $437.00
1Complete product number by replacing crosshatch (#) with appropriate coil digit from table below. 21NO aux contact front mounted.
Includes 1NO auxiliary contact integrated into MC* and CL* unless noted. Integrated contact is on left side on CL* contactors.
Replace crosshatch (#) in product number with coil digit. Coil Selection Coil Digit # for MC Contactors Coil Digit # for CL Contactors
6-16
12 B B
24 D D
Control Catalog
DC Voltage 48 G G
125 L K
250 S T
www.geindustrial.com
Rev. 4/16 Prices and data subject to change without notice
IEC Manual Motor Starters
Section 6
Integrated with Contactor Open, AC Operated Contactors High Interruption Capacity Product Number Structure for Modifications
Product Number Selection Instructions
Select product from table below. See page 6-19 for starter and contactor modifications.
Selection of the starter depends on the actual motor full load current and service factor. For motors with service factor of 1.15 or greater, use motor full load current to select the appropriate current range. For motors with a service factor less than 1.15, multiply the normal full load current by .9 for the current setting. Single phase applications require all three overload legs to be energized for proper operation. Use separate conductor to connect terminal T2 to L3. Connect power to L1 and L2 and apply load between T1 and T3.
Product Number Digits 1 G
2 P
3 2
4 1
5 N
6 A Starter Modifications
7 2
8 5
9 * (Coil)
10 A Contactor Modifications
45 mm (Rotary Operator) Individual, Group and Combination2 Installations Manual Motor Starter Type GPS1BH_ _ FLA Adjustment Range
Three Phase Horsepower @ 200V
0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4.0-6.3 6.3-10 0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4.0-6.3 6.3-10 9-13 11-16 14-20 19-25 24-32
Three Phase Horsepower @ 230V
Three Phase Horsepower @ 460V
Three Phase Horsepower @ 575V
1/4 1/2 3/4 1 2
1/3 1/2 3/4 1 1/2 3
1/2 3/4 1 2 3 5
1/2 3/4 1 1/2 3 5 5
1/4 1/2 3/4 1 2 3 3 5 7 1/2 10
1/3 1/2 3/4 1 1/2 3 3 5 5 7 1/2 10
1/2 3/4 1 2 3 5 7 1/2 10 10 15 20
1/2 3/4 1 1/2 3 5 7 1/2 10 10 15 20 25
Single Phase Horsepower @ 115V
Single Phase Horsepower @ 230V
1/8 1/4 1/2
1/10 1/6 1/3 1/2 1 1/2
1/8 1/4 1/2 1/2 1 1 1/2 1 1/2 2
1/10 1/6 1/3 1/2 1 1/2 2 2 3 3 5
Contactor Size MC1 MC1 MC1 MC1 MC1 MC1 MC1 MC1 MC1 MC1 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL01 CL02 CL25 CL04 CL04
Contactor Max Base Amps Included 9 9 9 9 9 9 9 9 9 9 10 10 10 10 10 10 10 10 10 10 13.8 17.5 22 32 32
No No No No No No No No No No No No No No No No No No No No No No No Yes Yes
Product Number1
List Price GO-10A2A
GP21AAM1*A GP21BAM1*A GP21CAM1*A GP21DAM1*A GP21EAM1*A GP21FAM1*A GP21GAM1*A GP21HAM1*A GP21JAM1*A GP21KAM1*A GP21AA00*A GP21BA00*A GP21CA00*A GP21DA00*A GP21EA00*A GP21FA00*A GP21GA00*A GP21HA00*A GP21JA00*A GP21KA00*A GP21LA01*A GP21MA02*A GP21NA25*A3 GP21PA04*A GP21RA04*A
$220.00 $220.00 $220.00 $220.00 $235.00 $235.00 $235.00 $235.00 $235.00 $235.00 $262.00 $262.00 $262.00 $262.00 $262.00 $277.00 $277.00 $277.00 $277.00 $277.00 $325.00 $340.00 $354.00 $424.00 $424.00
Product Number1
List Price GO-10A2A
GP22MA04*A GP22NA04*A GP22PA04*A GP22RA04*A GP22SA45*A3 GP22TA06*A4 GP22UA07*A4
$516.00 $516.00 $516.00 $516.00 $562.00 $611.00 $678.00
55 mm (Rotary Operator) Individual, Group and Combination2 Installations Manual Motor Starter Type GPS2BH_ _ FLA Adjustment Range
Three Phase Horsepower @ 200V
Three Phase Horsepower @ 230V
Three Phase Horsepower @ 460V
Three Phase Horsepower @ 575V
Single Phase Horsepower @ 115V
Single Phase Horsepower @ 230V
Contactor Size
3 5 7 1/2 10 10 15 15
5 5 7 1/2 10 10 15 20
10 10 15 20 25 30 40
10 15 20 25 25 40 50
1 1 1/2 2 2 3 3 5
2 3 3 5 5 7 1/2 10
CL04 CL04 CL04 CL04 CL45 CL06 CL07
11-16 14-20 19-25 24-32 28-40 35-50 45-63
Contactor Max Base Amps Included 32 32 32 32 34 48 62
Yes Yes Yes Yes Yes Yes Yes
1Complete product number by replacing asterisk (*) with appropriate coil digit from table below. For combination installation add short circuit alarm GPAE11LLA. 2For combination installation using GPS1BH_ _ starters add GPAPT1E terminal protector. See page 6-10 for field installation kits. For factory modified starters select t-z for
GPS2BH_
_ starters or x-z for GPS1BH starters on page 6-19. Maximum voltage for combination control is 277/480. 3N0 aux contact front mounted. 4N0-1NC aux contact front mounted.
Includes 1N0 auxiliary contact integrated into MC* and CL* unless noted. Integrated contact is on left side on CL* contactors.
Replace asterisk (*) in product number with coil digit. Coil Selection 60Hz 50Hz Coil Digit * for MC Contactors Coil Digit * for CL Contactors
Rev. 4/16 Prices and data subject to change without notice
24 — C —
24 24 — 1
www.geindustrial.com
120 110 J J
208 — M L
240 — — S
AC Voltage 240-277 277 — 220-230 N — — N
— 380 U —
480 380/400 — U
Control Catalog
— 415 — W
480 415 W —
600 500 Y Y
6-17
IEC Manual Motor Starters
Section 6
Integrated with Contactor Open, DC Operated Contactors High Interruption Capacity Product Number Structure for Modifications Select product from table below. See page 6-19 for starter and contactor modifications. Product Number Digits 1 G
2 P
3 3
4 1
5 N
6 A Starter Modifications
7 2
8 5
9 * (Coil)
10 A Contactor Modifications
45 mm High Interruption Capacity (Rotary Operator) Integrated with C2000 Contactor
Product Number Selection Instructions Selection of the starter depends on the actual motor full load current and service factor. For motors with service factor of 1.15 or greater, use motor full load current to select the appropriate current range. For motors with a service factor less than 1.15, multiply the normal full load current by .9 for the current setting. Single phase applications require all three overload legs to be energized for proper operation. Use separate conductor to connect terminal T2 to L3. Connect power to L1 and L2 and apply load between T1 and T3. 45 mm (Rotary Operator) Individual, Group or Combination2 Installation Manual Motor Starter Type GPS1BH_ _ FLA Adjustment Range 0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4.0-6.3 6.3-10 0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4.0-6.3 6.3-10 9-13 11-16 14-20 19-25 24-32
Three Phase Horsepower @ 200V
Three Phase Horsepower @ 230V
Three Phase Horsepower @ 460V
Three Phase Horsepower @ 575V
1/4 1/2 3/4 1 2
1/3 1/2 3/4 1 1/2 3
1/2 3/4 1 2 3 5
1/2 3/4 1 1/2 3 5 5
1/4 1/2 3/4 1 2 3 3 5 7 1/2 10
1/3 1/2 3/4 1 1/2 3 3 5 5 7 1/2 10
1/2 3/4 1 2 3 5 7 1/2 10 10 15 20
1/2 3/4 1 1/2 3 5 7 1/2 10 10 15 20 25
Single Phase Horsepower @ 115V
Single Phase Horsepower @ 230V
1/8 1/4 1/2
1/10 1/6 1/3 1/2 1 1/2
1/8 1/4 1/2 1/2 1 1 1/2 1 1/2 2
1/10 1/6 1/3 1/2 1 1/2 2 2 3 3 5
Contactor Size MC1 MC1 MC1 MC1 MC1 MC1 MC1 MC1 MC1 MC1 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL01 CL02 CL25 CL04 CL04
Contactor Max Base Amps Included 9 9 9 9 9 9 9 9 9 9 10 10 10 10 10 10 10 10 10 10 13.8 17.5 22 32 32
No No No No No No No No No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Product Number1 GP31AAM1#A GP31BAM1#A GP31CAM1#A GP31DAM1#A GP31EAM1#A GP31FAM1#A GP31GAM1#A GP31HAM1#A GP31JAM1#A GP31KAM1#A GP31AA00#A GP31BA00#A GP31CA00#A GP31DA00#A GP31EA00#A GP31FA00#A GP31GA00#A GP31HA00#A GP31JA00#A GP31KA00#A GP31LA01#A GP31MA02#A GP31NA25#A3 GP31PA04#A GP31RA04#A
List Price GO-10A2A $230.00 $230.00 $230.00 $230.00 $245.00 $245.00 $245.00 $245.00 $245.00 $245.00 $315.00 $315.00 $315.00 $315.00 $330.00 $330.00 $330.00 $330.00 $330.00 $330.00 $379.00 $393.00 $412.00 $467.00 $467.00
55 mm (Rotary Operator) Individual, Group or Combination2 Installation Manual Motor Starter Type GPS2BH_ _ FLA Adjustment Range 11-16 14-20 19-25 24-32 28-40
Three Phase Horsepower @ 200V
Three Phase Horsepower @ 230V
Three Phase Horsepower @ 460V
Three Phase Horsepower @ 575V
Single Phase Horsepower @ 115V
Single Phase Horsepower @ 230V
Contactor Size
3 5 7 1/2 10 10
5 5 7 1/2 10 10
10 10 15 20 25
10 15 20 25 25
1 1 1/2 2 2 3
2 3 3 5 5
CL04 CL04 CL04 CL04 CL45
Contactor Max Base Amps Included 32 32 32 2 34
Yes Yes Yes Yes Yes
Product Number1
List Price GO-10A2A
GP32MA04#A GP32NA04#A GP32PA04#A GP32RA04#A GP32SA45#A3
$559.00 $559.00 $559.00 $559.00 $646.00
1Complete product number by replacing crosshatch (#) with appropriate coil digit from table below. For combination installation add short circuit alarm GPAE11LA. 2For combination installation using GPS1BH_ _ starters, add GPAPT1E terminal protector. See page 6-10 for field installation kits. For factory modified starters select t-z for
GPS2BH_ _ starters or x-z for GPS1BH_ _ starters on page 6-19. Maximum voltage for combination control is 277/480. 31NO aux contact front mounted.
Includes 1NO auxiliary contact integrated into MC* and CL* unless noted. Integrated contact is on left side on CL* contactors.
Replace asterisk (#) in product number with coil digit. Coil Selection Coil Digit # for MC Contactors Coil Digit # for CL Contactors
6-18
12 B B
24 D D
Control Catalog
DC Voltage 48 G G
125 L K
250 S T
www.geindustrial.com
Rev. 4/16 Prices and data subject to change without notice
IEC Manual Motor Starters
Section 6
Integrated with Contactor Factory Installed Accessories Open Starter Modifications To specify modifications to your open starter, use the tables below to determine product number digit substitutions and list price adders. Open Starter Modification Product Number Structure Select product from tables on pages 6-15 to 6-18. Select starter and contactor modifications from tables below. 1 G
2 P
3 2
4 3
Product Number Digits 5 6 N A Starter Modifications
7 2
8 5
9 * (Coil)
10 A Contactor Modifications
Starter Modifications Replace product number Digit 6 with appropriate digit and add price adder to list price. Accessories Aux. Contact Aux. Contact Alarm Contact Aux. Contact Short Circuit Alarm Aux. Contact + (Short Circuit Alarm) Aux. Contact + (Short Circuit Alarm) + (Alarm Contact) Short Circuit Alarm + Terminal Cover* Short Circuit Alarm + Terminal Cover* Short Circuit Alarm + Terminal Cover* Short Circuit Alarm + (Aux. Contact) Short Circuit Alarm + (Aux. Contact)
Contacts 1NO 1NC 1NO 1NO-1NC 1NO-1NC 1NO + (1NO-1NC) 1NO-1NC + (1NO-1NC) + (1NO) 1NO + 1NC 1NO + 1NC 1NO + 1NC 1NO + (1NO) 1NC + (1NO)
Mounting Front Front Front Left Left Front (Left) Front (Left) (Front) Lateral Left Lateral Left Lateral Left Left Left
Product No. Digit 6 B C G P T U W X Y Z 1 3
List Price Adder, GO-10A2A $18.00 $18.00 $21.00 $27.00 $20.00 $40.00 $61.00 $32.00 $32.00 $32.00 $36.00 $36.00
*for GPS1BH_ _ units only
Contactor Modifications Replace product number Digit 10 with appropriate digit and add price adder to list price. Additional Auxiliary Contacts and Coil Surge Suppressors Standard Coil Surge Suppressor1 Auxiliary Contact Auxiliary Contact + Coil Surge Suppressor1 Auxiliary Contact Auxiliary Contact + Coil Surge Suppressor1 Auxiliary Contact Auxiliary Contact + Coil Surge Suppressor1
Contacts — — 1NO 1NO 1NC 1NC 1NO-1NC 1NO-1NC
Mounting by Contactor Type CL MC — — — — Front Left Front Left Front Left Front Left Front Front Front Front
Product No. Digit 10 MC,CL00, CL01 CL02, CL04 CL25, CL45 A2 A3 B B C C D D E E F F G G5 H H5
CL06, CL07 A4 B C D E F G H
List Price Adder, GO-10A2A $0.00 $27.00 $18.00 $45.00 $18.00 $45.00 $27.00 $54.00
1RC suppressor AC coil to 230V; diode suppressor for DC coil 2Includes internal 1NO holding interlock 3Includes 1NO front mounted auxiliary for holding interlock 4Includes 1NO front mounted auxiliary for holding interlock and 1NC auxiliary for general use 5Not available for CL25
Rev. 4/16 Prices and data subject to change without notice
www.geindustrial.com
Control Catalog
6-19
IEC Manual Motor Starters
Section 6
Enclosed Non-metal Enclosures Standard Interruption Capacity
45 mm Standard Interruption (Toggle Operator) Non-Metal Enclosure
45 mm (Toggle Operator) Individual Manual Motor Starter Type GPS1BS_ FLA Adjustment Range 0.1-0.16 0.16-.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4.0-6.3 6.3-10 9-13 11-16 14-20 19-25 0.1-0.16 0.16-.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4.0-6.3 6.3-10 9-13 11-16 14-20 19-25
6-20
Three Phase Horsepower @ 200V
Three Phase Horsepower @ 230V
Three Phase Horsepower @ 460V
Three Phase Horsepower @ 575V
1/4 1/2 3/4 1 2 3 3 5 7 1/2
1/3 1/2 3/4 1 1/2 3 3 3 5 7 1/2
1/2 3/4 1 2 3 5 7 1/2 7 1/2 10 15
1/2 3/4 1 1/2 3 3 5 10 10 15 20
1/4 1/2 3/4 1 2 3 3 5 7 1/2
1/3 1/2 3/4 1 1/2 3 3 3 5 7 1/2
1/2 3/4 1 2 3 5 7 1/2 7 1/2 10 15
1/2 3/4 1 1/2 3 3 5 10 10 15 20
Control Catalog
Single Phase Horsepower @ 115V
Single Phase Horsepower @ 230V
1/8 1/4 1/2 1/2 3/4 1 1 1/2
1/10 1/6 1/3 1/2 1 1/2 2 2 3 3
1/8 1/4 1/2 1/2 3/4 1 1 1/2
1/10 1/6 1/3 1/2 1 1/2 2 2 3 3
Enclosure Type
Product Number
List Price GO-10A2A
Non-Metal (Type 1) Non-Metal (Type 1) Non-Metal (Type 1) Non-Metal (Type 1) Non-Metal (Type 1) Non-Metal (Type 1) Non-Metal (Type 1) Non-Metal (Type 1) Non-Metal (Type 1) Non-Metal (Type 1) Non-Metal (Type 1) Non-Metal (Type 1) Non-Metal (Type 1) Non-Metal (Type 1) Non-Metal (Type 3R/12) Non-Metal (Type 3R/12) Non-Metal (Type 3R/12) Non-Metal (Type 3R/12) Non-Metal (Type 3R/12) Non-Metal (Type 3R/12) Non-Metal (Type 3R/12) Non-Metal (Type 3R/12) Non-Metal (Type 3R/12) Non-Metal (Type 3R/12) Non-Metal (Type 3R/12) Non-Metal (Type 3R/12) Non-Metal (Type 3R/12) Non-Metal (Type 3R/12)
GP13AAAAA1BA GP13BAAAA1BA GP13CAAAA1BA GP13DAAAA1BA GP13EAAAA1BA GP13FAAAA1BA GP13GAAAA1BA GP13HAAAA1BA GP13JAAAA1BA GP13KAAAA1BA GP13LAAAA1BA GP13MAAAA1BA GP13NAAAA1BA GP13PAAAA1BA GP13AAAAA3BA GP13BAAAA3BA GP13CAAAA3BA GP13DAAAA3BA GP13EAAAA3BA GP13FAAAA3BA GP13GAAAA3BA GP13HAAAA3BA GP13JAAAA3BA GP13KAAAA3BA GP13LAAAA3BA GP13MAAAA3BA GP13NAAAA3BA GP13PAAAA3BA
$143.00 $143.00 $143.00 $143.00 $155.00 $155.00 $155.00 $155.00 $155.00 $155.00 $175.00 $175.00 $175.00 $190.00 $161.00 $161.00 $161.00 $161.00 $173.00 $173.00 $173.00 $173.00 $173.00 $173.00 $193.00 $193.00 $193.00 $208.00
www.geindustrial.com
Rev. 4/16 Prices and data subject to change without notice
IEC Manual Motor Starters
Section 6
Enclosed Factory Installed Accessories Enclosed Starter Accessories Product Number Structure Select product from table on page 6-20. Select starter and enclosure accessories from tables below. Product Number Digits 1 G
2 P
3 1
4 3
5 A
6 7 A A Starter Auxiliary Contacts and Alarms
8 A
9 A
10 1
11 B Pilot Lights
12 A Pilot Lights
Starter Auxiliary Contacts and Alarms Replace Digit 6 in product number with digit corresponding to appropriate accessory. Accessory Auxiliary Contact Alarm + (Auxiliary Contact) Alarm + (Auxiliary Contact)
Contacts 1NO-1NC 1NO + (1NO) 1NC + (1NO)
List Price Adder, GO-10A2A $27.00 $36.00 $36.00
Product No. Digit 6 P 1 3
Pilot Lights Leads unwired for field configuration. Replace Digits 11 & 12 in product number with digits corresponding to lens color and voltage. Lens Color Red Green Clear
110/220 RJ GJ TJ
Voltage (50/60Hz) 380/440 RU GU TU
220/240 RN GN TN
480/500 RX GX TX
List Price Adder, GO-10A2A $27.00 $27.00 $27.00
600 RY GY TY
Modification Example Motor FLA is 1.9 amps. Requirement is for a Type 1 enclosed starter for 1 HP at 460V modified with a 1NO-NC aux contact and a red pilot light also at 460V. Step 1. Enclosed Starter 2. 1NO-1NC Aux. Contact 3. Red Pilot Light (460V) 4. Final Product No. & List Price
1 G G G G
2 P P P P
3 1 1 1 1
4 3 3 3 3
5 G G G G
6 A P P P
Digit No. 7 A A A A
8 A A A A
9 A A A A
10 1 1 1 1
11 B B R R
12 A A X X
List Price GO-10A2A $155.00 $27.00 $27.00 $209.00
Product selection from table on page 6-20 Digit #6: Starter Auxiliary Contacts and Alarms Digits #11 and #12: Pilot Lights
Rev. 4/16 Prices and data subject to change without notice
www.geindustrial.com
Control Catalog
6-21
IEC Manual Motor Starters
Section 6
Enclosed Metal Enclosures High Interruption Capacity Product Number Selection Instructions Selection of the starter depends on the actual motor full load current and service factor. For motors with service factor of 1.15 or greater, use motor full load current to select the appropriate current range. For motors with a service factor less than 1.15, multiply the normal full load current by .9 for the current setting. Single phase applications require all three overload legs to be energized for proper operation. Use separate conductor to connect terminal T2 to L3. Connect power to L1 and L2 and apply load between T1 and T3. 45 mm (Rotary Operator) Individual or Type E Combination1 Installation Manual Motor Starter Type GPS1BH_ _ FLA Adjustment Range 0.1-0.16 0.16-.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4.0-6.3 6.3-10 9-13 11-16 14-20 19-25 24-32 0.1-0.16 0.16-.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4.0-6.3 6.3-10 9-13 11-16 14-20 19-25 24-32
Three Phase Horsepower @ 200V
Three Phase Horsepower @ 230V
Three Phase Horsepower @ 460V
Three Phase Horsepower @ 575V
1/4 1/2 3/4 1 2 3 3 5 7 1/2 10
1/3 1/2 3/4 1 1/2 3 3 3 5 7 1/2 10
1/2 3/4 1 2 3 5 7 1/2 7 1/2 10 15 20
1/2 3/4 1 1/2 3 3 5 10 10 15 20 25
1/4 1/2 3/4 1 2 3 3 5 7 1/2 10
1/3 1/2 3/4 1 1/2 3 3 3 5 7 1/2 10
1/2 3/4 1 2 3 5 7 1/2 7 1/2 10 15 20
1/2 3/4 1 1/2 3 3 5 10 10 15 20 25
Single Phase Horsepower @ 115V
Single Phase Horsepower @ 230V
1/8 1/4 1/2 1/2 3/4 1 1 1/2 2
1/10 1/6 1/3 1/2 1 1/2 2 2 3 3 5
1/8 1/4 1/2 1/2 3/4 1 1 1/2 2
1/10 1/6 1/3 1/2 1 1/2 2 2 3 3 5
Enclosure Type
Product Number
List Price GO-10A2A
Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12)
GP11AAAAA5BA GP11BAAAA5BA GP11CAAAA5BA GP11DAAAA5BA GP11EAAAA5BA GP11FAAAA5BA GP11GAAAA5BA GP11HAAAA5BA GP11JAAAA5BA GP11KAAAA5BA GP11LAAAA5BA GP11MAAAA5BA GP11NAAAA5BA GP11PAAAA5BA GP11RAAAA5BA GP11AAAAA7BA GP11BAAAA7BA GP11CAAAA7BA GP11DAAAA7BA GP11EAAAA7BA GP11FAAAA7BA GP11GAAAA7BA GP11HAAAA7BA GP11JAAAA7BA GP11KAAAA7BA GP11LAAAA7BA GP11MAAAA7BA GP11NAAAA7BA GP11PAAAA7BA GP11RAAAA7BA
$190.00 $190.00 $190.00 $190.00 $205.00 $205.00 $205.00 $205.00 $205.00 $205.00 $230.00 $230.00 $230.00 $245.00 $245.00 $295.00 $295.00 $295.00 $295.00 $310.00 $310.00 $310.00 $310.00 $310.00 $310.00 $335.00 $335.00 $335.00 $350.00 $350.00
55 mm (Rotary Operator) Individual or Type E Combination1 Installation Manual Motor Starter Type GPS2BH_ _ FLA Adjustment Range 6.3-10 9-13 11-16 14-20 19-25 24-32 28-40 35-50 45-63 6.3-10 9-13 11-16 14-20 19-25 24-32 28-40 35-50 45-63
Three Phase Horsepower @ 200V
Three Phase Horsepower @ 230V
Three Phase Horsepower @ 460V
Three Phase Horsepower @ 575V
Single Phase Horsepower @ 115V
Single Phase Horsepower @ 230V
Enclosure Type
Product Number
List Price GO-10A2A
1 2 3 5 7 1/2 10 10 15 15 1 2 3 5 7 1/2 10 10 15 15
1 1/2 3 5 5 7 1/2 10 10 15 20 1 1/2 3 5 5 7 1/2 10 10 15 20
3 5 10 10 15 20 25 30 40 3 5 10 10 15 20 25 30 40
5 7 1/2 10 15 20 25 25 40 50 5 7 1/2 10 15 20 25 25 40 50
1/4 1/2 1 1 1/2 2 2 3 3 5 1/4 1/2 1 1 1/2 2 2 3 3 5
1/2 1 1/2 2 3 3 5 5 7 1/2 10 1/2 1 1/2 2 3 3 5 5 7 1/2 10
Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12)
GP12KAAAA5BA GP12LAAAA5BA GP12MAAAA5BA GP12NAAAA5BA GP12PAAAA5BA GP12RAAAA5BA GP12SAAAA5BA GP12TAAAA5BA GP12UAAAA5BA GP12KAAAA7BA GP12LAAAA7BA GP12MAAAA7BA GP12NAAAA7BA GP12PAAAA7BA GP12RAAAA7BA GP12SAAAA7BA GP12TAAAA7BA GP12UAAAA7BA
$390.00 $390.00 $390.00 $390.00 $390.00 $390.00 $420.00 $420.00 $447.00 $430.00 $430.00 $430.00 $430.00 $430.00 $430.00 $460.00 $460.00 $487.00
1For combination installation add short circuit alarm GPAE11LLA. For combination installation using GPS1BH—starters add GPAPT1E terminal protector. See page 6-10 for field
installation kits. For factory modified starters select t-z for GPS2BH—starters or x-z for GPS1BH—starters on page 6-23. Maximum voltage for combination control is 277/480. Enclosed Motor Starters (Without Contactors), Metallic Enclosures, Rotary Operated (Black Operator), Individual, Non-combination or Type E Combination Installation.
6-22
Control Catalog
www.geindustrial.com
Rev. 4/16 Prices and data subject to change without notice
IEC Manual Motor Starters
Section 6
Enclosed Factory Installed Accessories Modifications & Accessories for Enclosed Motor Starters, Metallic Enclosures, Rotary Operated To specify modifications to your enclosed starter, use the tables below to determine product number digit substitutions and list price adders. Enclosed Starter Modification Product Number Structure Select product from tables on page 6-22. Select starter, handle, or enclosure accessory from tables below. Product Number Digits 1 G
2 P
3 1
4 1
5 G
6 7 A A Starter Auxiliary Contacts and Alarms
8 A
9 A
10 11 7 B Enclosure Type/ Pilot Light Operator Handle Color
12 A Pilot Light
Starter Auxiliary Contacts, Short Circuit Alarm & Alarm Contact Replace Digit 6 in product number with digit corresponding to appropriate accessory. Accessories Aux. Contact Aux. Contact Alarm Contact Aux. Contact Short Circuit Alarm Aux. Contact + (Short Circuit Alarm) Aux. Contact + (Short Circuit Alarm) + [Alarm Contact] Short Circuit Alarm + Terminal Cover* Short Circuit Alarm + Terminal Cover* Short Circuit Alarm + Terminal Cover* Alarm + (Aux. Contact) Alarm + (Aux. Contact)
Contacts 1NO 1NC 1NO 1NO-1NC 1NO-1NC 1NO + (1NO-1NC) 1NO-1NC + (1N0-1NC) + [1NO] 1NO + 1NC 1NO + 1NC 1NO + 1NC 1NO + (1N0) 1NC + (1NO)
Product No. Digit 6 B C G P T U W X Y Z 1 3
Mounting Front Front Front Left Left Front (Left) Front (Left) [Front] Lateral Left Lateral Left Lateral Left Left Left
List Price Adder, GO-10A2A $18.00 $18.00 $21.00 $27.00 $20.00 $40.00 $61.00 $32.00 $32.00 $32.00 $36.00 $36.00
*for GPS1BH_ _ units only
Red/Yellow Rotary Operator Replace Digit 10 in product number with digit corresponding to enclosure type. Product No. Digit 10 6 8
Enclosure Type Type 11 Type 3R/12
List Price Adder, GO-10A2A $0.00 $0.00
1For use only with GPS2BH_ _ starters.
Pilot Lights Includes both red and green lenses for field installation. Replace Digits 11 & 12 in product number with digits corresponding to voltage. Product No. Digits 11 & 12 GC GJ GL GN GS GX GY
Voltage (60 Hz) 24 120 208 277 240 460 600
List Price Adder, GO-10A2A $96.00 $96.00 $96.00 $96.00 $96.00 $96.00 $96.00
Modification Example Motor FLA is 1.9 amps. Requirement is for a Type 1 enclosed starter for 1 HP at 460V modified with a 1NO-NC aux contact, a red/ yellow operator and a pilot light also at 460V. Step 1. Enclosed Starter 2. 1NO-1NC Aux. Contact 3. Red/Yellow Operator 4. Red Pilot Light (460V) 5. Final Product No. & List Price
1 G G G G G
2 P P P P P
3 1 1 1 1 1
4 1 1 1 1 1
5 G G G G G
6 A P P P P
Digit No. 7 A A A A A
8 A A A A A
9 A A A A A
10 7 7 8 8 8
11 B B B G G
12 A A A X X
List Price GO-10A2A $310.00 $27.00 $0.00 $96.00 $433.00
Product selection from table on page 6-22 Digit #6: Starter Auxiliary Contacts and Alarms Digit #10: Red/Yellow Rotary Operator/Enclosure Type Digit #11 and #12: Pilot Light
Rev. 4/16 Prices and data subject to change without notice
www.geindustrial.com
Control Catalog
6-23
IEC Manual Motor Starters
Section 6
Integrated with Contactor Enclosed, AC Operated Contactors High Interruption Capacity Product Number Selection Instructions Selection of the starter depends on the actual motor full load current and service factor. For motors with service factor of 1.15 or greater, use motor full load current to select the appropriate current range. For motors with a service factor less than 1.15, multiply the normal full load current by .9 for the current setting. Single phase applications require all three overload legs to be energized for proper operation. Use separate conductor to connect terminal T2 to L3. Connect power to L1 and L2 and apply load between T1 and T3. Select product from tables. See pages 6-28 and 6-29 for starter, contactor or enclosure modifications. 45 mm (Rotary Operator) Individual, Non-Combination or Combination2 Installation Manual Motor Starter Type GPS1BH_ _ FLA Adjustment Range 0.1-0.16 0.16-.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4.0-6.3 6.3-10 0.1-0.16 0.16-.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4.0-6.3 6.3-10 9-13 11-16 14-20 19-25 24-32 0.1-0.16 0.16-.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4.0-6.3 6.3-10 0.1-0.16 0.16-.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4.0-6.3 6.3-10 9-13 11-16 14-20 19-25 24-32
Three Phase Horsepower @ 200V
Three Phase Horsepower @ 230V
Three Phase Horsepower @ 460V
Three Phase Horsepower @ 575V
Single Phase Horsepower @ 115V
Single Phase Horsepower @ 230V
1/4 1/2 3/4 1 2
1/3 1/2 3/4 1 1/2 3
1/2 3/4 1 2 3 5
1/2 3/4 1 1/2 3 5 7 1/2
1/8 1/4 1/2
1/10 1/6 1/3 1/2 1 1/2
1/4 1/2 3/4 1 2 3 3 5 7 1/2 10
1/3 1/2 3/4 1 1/2 3 3 5 5 7 1/2 10
1/2 3/4 1 2 3 5 7 1/2 10 10 15 20
1/2 3/4 1 1/2 3 5 7 1/2 10 10 15 20 25
1/8 1/4 1/2 1/2 1 1 1/2 1 1/2 2
1/10 1/6 1/3 1/2 1 1/2 2 2 3 3 5
1/4 1/2 3/4 1 2
1/3 1/2 3/4 1 1/2 3
1/2 3/4 1 2 3 5
1/2 3/4 1 1/2 3 5 7 1/2
1/8 1/4 1/2
1/10 1/6 1/3 1/2 1 1/2
1/4 1/2 3/4 1 2 3 3 5 7 1/2 10
1/3 1/2 3/4 1 1/2 3 3 5 5 7 1/2 10
1/2 3/4 1 2 3 5 7 1/2 10 10 15 20
1/2 3/4 1 1/2 3 5 7 1/2 10 10 15 20 25
1/8 1/4 1/2 1/2 1 1 1/2 1 1/2 2
1/10 1/6 1/3 1/2 1 1/2 2 2 3 3 5
Contactor Size
Contactor Max Amps
Enclosure Type
MC1 MC1 MC1 MC1 MC1 MC1 MC1 MC1 MC1 MC1 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL01 CL02 CL25 CL04 CL04 MC1 MC1 MC1 MC1 MC1 MC1 MC1 MC1 MC1 MC1 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL01 CL02 CL25 CL04 CL04
9 9 9 9 9 9 9 9 9 9 10 10 10 10 10 10 10 10 10 10 13.8 17.5 22 32 32 9 9 9 9 9 9 9 9 9 9 10 10 10 10 10 10 10 10 10 10 13.8 17.5 22 32 32
Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12)
Product Number1
List Price GO-10A2A
GP26AAM1*A1AA GP26BAM1*A1AA GP26CAM1*A1AA GP26DAM1*A1AA GP26EAM1*A1AA GP26FAM1*A1AA GP26GAM1*A1AA GP26HAM1*A1AA GP26JAM1*A1AA GP26KAM1*A1AA GP26AA00*A1AA GP26BA00*A1AA GP26CA00*A1AA GP26DA00*A1AA GP26EA00*A1AA GP26FA00*A1AA GP26GA00*A1AA GP26HA00*A1AA GP26JA00*A1AA GP26KA00*A1AA GP26LA01*A1AA GP26MA02*A1AA GP26NA25*A1AA3 GP26PA04*A1AA GP26RA04*A1AA GP26AAM1*A3AA GP26BAM1*A3AA GP26CAM1*A3AA GP26DAM1*A3AA GP26EAM1*A3AA GP26FAM1*A3AA GP26GAM1*A3AA GP26HAM1*A3AA GP26JAM1*A3AA GP26KAM1*A3AA GP26AA00*A3AA GP26BA00*A3AA GP26CA00*A3AA GP26DA00*A3AA GP26EA00*A3AA GP26FA00*A3AA GP26GA00*A3AA GP26HA00*A3AA GP26JA00*A3AA GP26KA00*A3AA GP26LA01*A3AA GP26MA02*A3AA GP26NA25*A3AA3 GP26PA04*A3AA GP26RA04*A3AA
$411.00 $411.00 $411.00 $411.00 $426.00 $426.00 $426.00 $426.00 $426.00 $426.00 $453.00 $453.00 $453.00 $453.00 $468.00 $468.00 $468.00 $468.00 $468.00 $468.00 $516.00 $531.00 $545.00 $589.00 $589.00 $456.00 $456.00 $456.00 $456.00 $471.00 $471.00 $471.00 $471.00 $471.00 $471.00 $498.00 $498.00 $498.00 $498.00 $513.00 $513.00 $513.00 $513.00 $513.00 $513.00 $561.00 $576.00 $590.00 $634.00 $634.00
1Complete product number by replacing asterisk (*) with appropriate coil digit from table below. 2For combination installation add short circuit alarm GPAE11LLA. For combination installation using GPS1BH—starters add GPAPT1E terminal protector. See page 6-10 for field
installation kits. For factory modified starters select t-z for GPS2BH—starters or x-z for GPS1BH—starters on page 6-28. Maximum voltage for combination control is 277/480. 31NO aux contact front mounted.
Enclosed Assembled Motor Starters with AC Contactors, Rotary Operated (Black Operator), Individual Non-Combination or Combination Installation. Includes 1NO auxiliary contact integrated into MC* and CL* unless noted. Integrated contact is on left side of CL* contactors.
Replace asterisk (*) in product number with coil digit. Coil Selection 60Hz 50Hz Coil Digit* for MC Contactors Coil Digit* for CL Contactors
6-24
24 — C —
24 24 — 1
Control Catalog
120 110 J J
208 — M L
240 — — S
AC Voltage 240-277 277 — 220-230 N — — N
www.geindustrial.com
— 380 U —
480 380/400 — U
— 415 — W
480 415 W —
600 500 Y Y
Rev. 4/16 Prices and data subject to change without notice
IEC Manual Motor Starters
Section 6
Integrated with Contactor Enclosed, AC Operated Contactors High Interruption Capacity
High Interruption Capacity (Rotary Operator), Metal Enclosure, Integrated with AC Contactor
55 mm (Rotary Operator) Individual, Non-Combination or Combination2 Installation Manual Motor Starter Type GPS2BH_ _ FLA Adjustment Range 11-16 14-20 19-25 24-32 28-40 35-50 45-63 11-16 14-20 19-25 24-32 28-40 35-50 45-63
Three Phase Horsepower @ 200V
Three Phase Horsepower @ 230V
Three Phase Horsepower @ 460V
Three Phase Horsepower @ 575V
Single Phase Horsepower @ 115V
Single Phase Horsepower @ 230V
Contactor Size
Contactor Max Amps
Enclosure Type
Product Number1
List Price GO-10A2A
3 5 7 1/2 10 10 15 15 3 5 7 1/2 10 10 15 15
5 5 7 1/2 10 10 15 20 5 5 7 1/2 10 10 15 20
10 10 15 20 25 30 40 10 10 15 20 25 30 40
10 15 20 25 25 40 50 10 15 20 25 25 40 50
1 1 1/2 2 2 3 3 5 1 1 1/2 2 2 3 3 5
2 3 3 5 5 7 1/2 10 2 3 3 5 5 7 1/2 10
CL04 CL04 CL04 CL04 CL45 CL06 CL07 CL04 CL04 CL04 CL04 CL45 CL06 CL07
32 32 32 32 34 48 62 32 32 32 32 34 48 62
Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12)
GP22MA04*A1AA GP22NA04*A1AA GP22PA04*A1AA GP22RA04*A1AA GP22SA45*A1AA3 GP22TA06*A1AA4 GP22UA07*A1AA4 GP22MA04*A3AA GP22NA04*A3AA GP22PA04*A3AA GP22RA04*A3AA GP22SA45*A3AA3 GP22TA06*A3AA3 GP22UA07*A3AA3
$681.00 $681.00 $681.00 $681.00 $727.00 $776.00 $796.00 $726.00 $726.00 $726.00 $726.00 $772.00 $821.00 $888.00
1Complete product number by replacing asterisk (*) with appropriate coil digit from table below. 2For combination installation add short circuit alarm GPAE11LLA. For combination installation using GPS1BH—starters add GPAPT1E terminal protector. See page 6-10 for field
installation kits. For factory modified starters select t-z for GPS2BH—starters or x-z for GPS1BH—starters on page 6-28. Maximum voltage for combination control is 277/480. 31NO aux contact front mounted. 41NO-1NC aux contact front mounted.
Enclosed Assembled Motor Starters with AC Contactors, Rotary Operated (Black Operator), Individual Non-Combination or Combination Installation Includes 1NO auxiliary contact integrated into MC* and CL* unless noted. Integrated contact is on left side of CL* contactors.
Replace asterisk (*) in product number with coil digit. Coil Selection 60Hz 50Hz Coil Digit* for MC Contactors Coil Digit* for CL Contactors
Rev. 4/16 Prices and data subject to change without notice
24 — C —
24 24 — 1
www.geindustrial.com
120 110 J J
208 — M L
240 — — S
AC Voltage 240-277 277 — 220-230 N — — N
— 380 U —
480 380/400 — U
Control Catalog
— 415 — W
480 415 W —
600 500 Y Y
6-25
IEC Manual Motor Starters
Section 6
Integrated with Contactor Enclosed, DC Operated Contactors High Interruption Capacity Product Number Selection Instructions Selection of the starter depends on the actual motor full load current and service factor. For motors with service factor of 1.15 or greater, use motor full load current to select the appropriate current range. For motors with a service factor less than 1.15, multiply the normal full load current by .9 for the current setting. Single phase applications require all three overload legs to be energized for proper operation. Use separate conductor to connect terminal T2 to L3. Connect power to L1 and L2 and apply load between T1 and T3. Select product from tables. See pages 6-28 and 6-29 for starter, contactor or enclosure modifications. 45 mm (Rotary Operator) Individual, Non-Combination or Combination2 Installation Manual Motor Starter Type GPS1BH_ _ FLA Adjustment Range 0.1-0.16 0.16-.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4.0-6.3 6.3-10 0.1-0.16 0.16-.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4.0-6.3 6.3-10 9-13 11-16 14-20 19-25 24-32 0.1-0.16 0.16-.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4.0-6.3 6.3-10 0.1-0.16 0.16-.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4.0-6.3 6.3-10 9-13 11-16 14-20 19-25 24-32
Three Phase Horsepower @ 200V
Three Phase Horsepower @ 230V
Three Phase Horsepower @ 460V
Three Phase Horsepower @ 575V
1/4 1/2 3/4 1 2
1/3 1/2 3/4 1 1/2 3
1/2 3/4 1 2 3 5
1/2 3/4 1 1/2 3 5 5
1/4 1/2 3/4 1 2 3 3 5 7 1/2 10
1/3 1/2 3/4 1 1/2 3 3 5 5 7 1/2 10
1/2 3/4 1 2 3 5 7 1/2 10 10 15 20
1/2 3/4 1 1/2 3 5 7 1/2 10 10 15 20 25
1/4 1/2 3/4 1 2
1/3 1/2 3/4 1 1/2 3
1/2 3/4 1 2 3 5
1/2 3/4 1 1/2 3 5 5
1/4 1/2 3/4 1 2 3 3 5 7 1/2 10
1/3 1/2 3/4 1 1/2 3 3 5 5 7 1/2 10
1/2 3/4 1 2 3 5 7 1/2 10 10 15 20
1/2 3/4 1 1/2 3 5 7 1/2 10 10 15 20 25
Single Phase Horsepower @ 115V
Single Phase Horsepower @ 230V
1/8 1/4 1/2
1/10 1/6 1/3 1/2 1 1/2
1/8 1/4 1/2 1/2 1 1 1/2 1 1/2 2
1/10 1/6 1/3 1/2 1 1/2 2 2 3 3 5
1/8 1/4 1/2
1/10 1/6 1/3 1/2 1 1/2
1/8 1/4 1/2 1/2 1 1 1/2 1 1/2 2
1/10 1/6 1/3 1/2 1 1/2 2 2 3 3 5
Contactor Size
Contactor Max Amps
Enclosure Type
MC1 MC1 MC1 MC1 MC1 MC1 MC1 MC1 MC1 MC1 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL01 CL02 CL25 CL04 CL04 MC1 MC1 MC1 MC1 MC1 MC1 MC1 MC1 MC1 MC1 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL01 CL02 CL25 CL04 CL04
9 9 9 9 9 9 9 9 9 9 10 10 10 10 10 10 10 10 10 10 13.8 17.5 22 32 32 9 9 9 9 9 9 9 9 9 9 10 10 10 10 10 10 10 10 10 10 13.8 17.5 22 32 32
Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12)
Product Number1 GP36AAM1#A1AA GP36BAM1#A1AA GP36CAM1#A1AA GP36DAM1#A1AA GP36EAM1#A1AA GP36FAM1#A1AA GP36GAM1#A1AA GP36HAM1#A1AA GP36JAM1#A1AA GP36KAM1#A1AA GP36AA00#A1AA GP36BA00#A1AA GP36CA00#A1AA GP36DA00#A1AA GP36EA00#A1AA GP36FA00#A1AA GP36GA00#A1AA GP36HA00#A1AA GP36JA00#A1AA GP36KA00#A1AA GP36LA01#A1AA GP36MA02#A1AA GP36NA25#A1AA3 GP36PA04#A1AA GP36RA04#A1AA GP36AAM1#A3AA GP36BAM1#A3AA GP36CAM1#A3AA GP36DAM1#A3AA GP36EAM1A3AA GP36FAM1#A3AA GP36GAM1#A3AA GP36HAM1#A3AA GP36JAM1#A3AA GP36KAM1#A3AA GP36AA00#A3AA GP36BA00#A3AA GP36CA00#A3AA GP36DA00#A3AA GP36EA00#A3AA GP36FA00#A3AA GP36GA00#A3AA GP36HA00#A3AA GP36JA00#A3AA GP36KA00#A3AA GP36LA01#A3AA GP36MA02#A3AA GP36NA25#A3AA3 GP36PA04#A3AA GP36RA04#A3AA
List Price GO-10A2A $421.00 $421.00 $421.00 $421.00 $436.00 $436.00 $436.00 $436.00 $436.00 $480.00 $480.00 $480.00 $480.00 $480.00 $495.00 $495.00 $495.00 $495.00 $495.00 $495.00 $544.00 $558.00 $577.00 $632.00 $632.00 $466.00 $466.00 $466.00 $466.00 $481.00 $481.00 $481.00 $481.00 $481.00 $525.00 $525.00 $525.00 $525.00 $525.00 $540.00 $540.00 $540.00 $540.00 $540.00 $540.00 $589.00 $603.00 $622.00 $677.00 $677.00
1Complete product number by replacing crosshatch (#) with appropriate coil digit from table below. 2For combination installation add short circuit alarm GPAE11LLA. For combination installation using GPS1BH—starters add GPAPT1E terminal protector. See page 6-10 for field
installation kits. For factory modified starters select t-z for GPS2BH—starters or x-z for GPS1BH—starters on page 6-28. Maximum voltage for combination control is 277/480. 31NO aux contact front mounted.
Includes 1NO auxiliary contact integrated into MC* and CL* unless noted. Integrated contact is on left side on CL* contactors.
Replace crosshatch (#) in product number with coil digit. Coil Selection Coil Digit # for MC Contactors Coil Digit # for CL Contactors
6-26
12 B B
24 D D
Control Catalog
DC Voltage 48 G G
125 L K
250 S T
www.geindustrial.com
Rev. 4/16 Prices and data subject to change without notice
IEC Manual Motor Starters
Section 6
Integrated with Contactor Enclosed, DC Operated Contactors High Interruption Capacity
High Interruption Capacity (Rotary Operator), Metal Enclosure, Integrated with DC Contactor
55 mm (Rotary Operator) Individual, Non-Combination or Combination2 Installation Manual Motor Starter Type GPS2BH_ _ FLA Adjustment Range 11-16 14-20 19-25 24-32 28-40 11-16 14-20 19-25 24-32 28-40
Three Phase Horsepower @ 200V
Three Phase Horsepower @ 230V
Three Phase Horsepower @ 460V
Three Phase Horsepower @ 575V
Single Phase Horsepower @ 115V
Single Phase Horsepower @ 230V
Contactor Size
Contactor Max Amps
Enclosure Type
3 5 7 1/2 10 10 3 5 7 1/2 10 10
5 5 7 1/2 10 10 5 5 7 1/2 10 10
10 10 15 20 25 10 10 15 20 25
10 15 20 25 25 10 15 20 25 25
1 1 1/2 2 2 3 1 1 1/2 2 2 3
2 3 3 5 5 2 3 3 5 5
CL04 CL04 CL04 CL04 CL45 CL04 CL04 CL04 CL04 CL45
32 32 32 32 34 32 32 32 32 34
Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 1) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12) Metal (Type 3R/12)
Product Number1 GP32MA04#A1AA GP32NA04#A1AA GP32PA04#A1AA GP32RA04#A1AA GP32SA45#A1AA3 GP32MA04#A3AA GP32NA04#A3AA GP32PA04#A3AA GP32RA04#A3AA GP32SA45#A3AA3
List Price GO-10A2A $724.00 $724.00 $724.00 $724.00 $811.00 $769.00 $769.00 $769.00 $769.00 $856.00
1Complete product number by replacing crosshatch (#) with appropriate coil digit from table below. 2For combination installation add short circuit alarm GPAE11LLA. For combination installation using GPS1BH—starters add GPAPT1E terminal protector. See page 6-10 for field
installation kits. For factory modified starters select t-z for GPS2BH—starters or x-z for GPS1BH—starters on page 6-28. Maximum voltage for combination control is 277/480. 31NO aux contact front mounted.
Includes 1NO auxiliary contact integrated into MC* and CL* unless noted. Integrated contact is on left side on CL* contactors.
Replace crosshatch (#) in product number with coil digit. Coil Selection Coil Digit # for MC Contactors Coil Digit # for CL Contactors
Rev. 4/16 Prices and data subject to change without notice
12 B B
24 D D
DC Voltage 48 G G
www.geindustrial.com
125 L K
250 S T
Control Catalog
6-27
IEC Manual Motor Starters
Section 6
Integrated with Contactor Factory Installed Accessories Enclosed Assembled Starters, Metallic Enclosures, Rotary Operated To specify modifications to your enclosed starter, use the tables below to determine product number digit substitutions and list price adders. Enclosed Starter Modification Product Number Structure Select product from tables on pages 6-24 through 6-27. Select starter, contactor, or enclosure modifications from table below. Product Number Digits 1 G
2 P
3 2
4 6
5 G
6
7 0
8 0
9 * (Coil)
Starter Auxiliary Contact and Alarm
10 11 A Contactor Enclosure Type/ Auxiliary Contact Operator Handle and Surge Suppressor Color
12
13
CPT
Pilot Devices
Starter Auxiliary Contact and Alarm Replace product number Digit 6 with appropriate digit and add price adder to list price. Accessories Aux. Contact Aux. Contact Alarm Contact Aux. Contact Short Circuit Alarm Aux. Contact + (Short Circuit Alarm) Aux. Contact + (Short Circuit Alarm) + [Alarm Contact] Short Circuit Alarm + Terminal Cover Short Circuit Alarm + Terminal Cover Short Circuit Alarm + Terminal Cover Alarm + (Aux. Contact) Alarm + (Aux. Contact)
Contacts 1NO 1NC 1NO 1NO-1NC 1NO-1NC 1NO + (1NO-1NC) 1NO-1NC + (1NO-1NC) + [1NO]
Mounting Front Front Front Left Left Front (Left) Front (Left) [Front]
Product No. Digit 6 B C G P T U W
List Price Adder, GO-10A2A $18.00 $18.00 $21.00 $27.00 $20.00 $40.00 $61.00
1NO + 1NC 1NO + 1NC 1NO + 1NC 1NO + (1NO) 1NC + (1NO)
Lateral Left Lateral Left Lateral Left Left Left
X Y Z 1 3
$32.00 $32.00 $32.00 $36.00 $36.00
Replace asterisk (*) in product number with coil digit. Coil Selection – AC Voltage 60Hz 50Hz Coil Digit* for MC Contactors Coil Digit* for CL Contactors
24 — C —
24 24 — 1
120 110 J J
208 — M L
240 — — S
AC Voltage 240-277 277 — 220-230 N — — N
— 380 U —
480 380/400 — U
— 415 — W
480 415 W —
600 500 Y Y
Coil Selection – DC Voltage Coil Digit * for MC Contactors Coil Digit * for CL Contactors
12 B B
DC Voltage 48 G G
24 D D
125 L K
250 S T
Contactor Auxiliary Contact and Surge Suppressor Replace product number Digit 10 with appropriate digit and add price adder to list price.
Product No. Digit 10 Product No. Digit 10 Additional Auxiliary Contacts and Coil Surge Suppressors Standard Coil Surge Suppressor1 Auxiliary Contact Auxiliary Contact + Coil Surge Suppressor1 Auxiliary Contact Auxiliary Contact + Coil Surge Suppressor1 Auxiliary Contact Auxiliary Contact + Coil Surge Suppressor1
Contacts — — 1NO 1NO 1NC 1NC 1NO-1NC 1NO-1NC
Mounting by Contactor Type CL MC — — — — Front Left Front Left Front Left Front Left Front Front Front Front
MC,CL00, CL01 CL02, CL04 A2 B C D E F G H
CL25, CL45 A3 B C D E F G5 H5
CL06, CL07 A4 B C D E F G H
List Price Adder, GO-10A2A $0.00 $27.00 $18.00 $45.00 $18.00 $45.00 $27.00 $54.00
1RC suppressor AC coil to 230V; diode suppressor for DC coil 2Includes internal 1NO holding interlock 3Includes 1NO front mounted auxiliary for holding interlock 4Includes 1NO front mounted auxiliary for holding interlock and 1NC auxiliary for general use 5Not available for CL25
6-28
Control Catalog
www.geindustrial.com
Rev. 4/16 Prices and data subject to change without notice
IEC Manual Motor Starters
Section 6
Integrated with Contactor Factory Installed Accessories Enclosed Assembled Starters, Metallic Enclosures, Rotary Operated Red/Yellow Rotary Operator Replace Digit 11 in product number with digit corresponding to enclosure type. Oversize enclosure is required for CPT and reversing control or optional if more space is desired. Replace product number Digit 11 with appropriate digit and add price adder to list price. If selecting CPT (below), oversize enclosure is included and this modification is not required. See CPT table. Standard Enclosure List Price Adder, Product No. Digit 11 GO-10A2A 2 $0.00 4 $0.00
Enclosure Type Type 1 Type 3R/12
Oversize Enclosure Yellow/Red Operator – Product No. Digit 11 6 8
Black Operator – Product No. Digit 11 5 7
List Price Adder, GO-10A2A $70.00 $70.00
Control Power Transformer Includes oversized enclosure (required for CPT). Replace product number Digits 11 and 12 with appropriate digits and add price adder to list price. Voltage Primary 480/240V 208V 277V 575V 480/240V 208V 277V 575V
Secondary 120V 120V 120V 120V 24V 24V 24V 24V
Operator Color Black Black Black Black Black Black Black Black
50VA Product No. Digits 11 & 12 Type 1 Type 3R/12 5B 7B 5C 7C 5D 7D 5E 7E 5K 7K 5L 7L 5M 7M 5N 7N
List Price Adder, GO-10A2A $230.00 $230.00 $230.00 $230.00 $230.00 $230.00 $230.00 $230.00
150VA Product No. Digits 11 & 12 Type 1T Type 3R/12 5F 7F 5G 7G 5H 7H 5J 7J 5P 7P 5Q 7Q 5R 7R 5S 7S
List Price Adder, GO-10A2A $275.00 $275.00 $275.00 $275.00 $275.00 $275.00 $275.00 $275.00
For red/yellow operator, replace 5 with 6, or 7 with 8 in Digit 11 above.
Pilot Devices Replace product number Digit 13 with appropriate digit and add price adder to list price. Pilot Device START/STOP Push Button START/STOP Mushroom Head Push Button START/STOP Push Button with Red/Green ON Pilot Light1 START/STOP Push Button with Red/Green OFF Pilot Light thru Aux.1 ON/OFF Selector Switch ON/OFF Selector Switch with Red/Green ON Pilot Light1 ON/OFF Selector Switch with Red/Green OFF Pilot Light thru Aux.1 H-O-A Selector Switch H-O-A Selector Switch with Red/Green ON Pilot Light1 H-O-A Selector Switch with Red/Green OFF Pilot Light thru Aux.1 Red/Green OFF Pilot Light thru Aux.1 H-O-A Selector Switch with START Push Button
Product No. Digit 13 B C D E F G H J K L M N
List Price Adder, GO-10A2A $144.00 $144.00 $288.00 $315.00 $72.00 $216.00 $243.00 $72.00 $216.00 $243.00 $171.00 $144.00
1Pilot lights comes with both red and green lenses for field installation.
Rev. 4/16 Prices and data subject to change without notice
www.geindustrial.com
Control Catalog
6-29
IEC Manual Motor Starters
Section 6
Outline Drawings Outlines and Dimensions mm (in.) For Estimating Only
Manual Motor Starter - GPS1BS_ (toggle)
Manual Motor Starter - GPS2BH_ (rotary)
Manual Motor Starter - GPS1BH_ (rotary)
6-30
Control Catalog
www.geindustrial.com
Rev. 4/16 Prices and data subject to change without notice
IEC Manual Motor Starters
Section 6
Outline Drawings Outlines and Dimensions mm (in.) For Estimating Only
GPAC_ _FBA Auxiliary Contact Blocks - Frontal
GPAC_ _LLA Auxiliary Contact Blocks - Lateral Left
GPAL_ _ _FRA Alarm Contact Blocks - Frontal
GPAD_ _ _ _LLA Alarm Contact Blocks - Lateral
GPASLR_ _ _/GPAULR_ _ _Shunt and Undervoltage - Trip Devices
GPAE11LLA Short Circuit Contact Block
Rev. 4/16 Prices and data subject to change without notice
www.geindustrial.com
Control Catalog
6-31
IEC Manual Motor Starters
Section 6
Outline Drawings Outlines and Dimensions mm (in.) For Estimating Only
6-32
GPS1BS_ (toggle) + Auxiliaries
GPS1BH_ (rotary) + Auxiliaries
GPS1BS_ (toggle) + Undervoltage Trip Device w/2NO Contacts
GPS2* + Auxiliaries
Control Catalog
www.geindustrial.com
Rev. 4/16 Prices and data subject to change without notice
IEC Manual Motor Starters
Section 6
Outline Drawings Outlines and Dimensions mm (in.) For Estimating Only
92.7 (3. 64) 64.6 (2.54) 28.7 (1.13)
4 (. 15)
187.3(7.37)
44.9 (1.76)
120.4 (4.74) 125 (4.92) 38. 6 (1.51)
81.9 (3. 22) 46 (1.81)
8.3 14.2 (. 55) (.33) 45 (1.77)
MC...A
MC...C
Assembled Starter - GPS1_ (toggle) + Minicontactor MC
CL00A-CL01A-CL02A
7.5 (. 29) 50.5 (1.98) 78 (3. 07)
CL25A
76.7 (3. 01) 117.4 (4.62) 135.1 (5.31)
CL25D
Assembled Starter - GPS1BS_ (toggle) + Contactor CL25
CL00D -CL01D -CL02D
Assembled Starter - GPS1BS_ (toggle) + Contactor CL00-CL01-CL02
Rev. 4/16 Prices and data subject to change without notice
www.geindustrial.com
Control Catalog
6-33
IEC Manual Motor Starters
Section 6
Outline Drawings Outlines and Dimensions mm (in.) For Estimating Only
CL03A-CL04A
CL03D-CL04D
Assembled Starter GPS2* + Contactor CL03-CL04
CL45A
CL45D
Assembled Starter GPS2* + Contactor CL45
6-34
Control Catalog
www.geindustrial.com
Rev. 4/16 Prices and data subject to change without notice
IEC Manual Motor Starters
Section 6
Outline Drawings Outlines and Dimensions mm (in.) For Estimating Only
CL06A-CL07A-CL08A Assembled Starter GPS2* + Contactor CL06-CL08
External Handle Operator
Rev. 4/16 Prices and data subject to change without notice
www.geindustrial.com
Control Catalog
6-35
IEC Manual Motor Starters
Section 6
Outline Drawings Outlines and Dimensions mm (in.) For Estimating Only
Non-metal Enclosure for GPS1BSAA-GPS1BSAP Surface Mounting
Non-metal Enclosure for GPS1BSAA-GPS1BSAP Surface Mounting with Padlocking Device
6-36
Control Catalog
www.geindustrial.com
Rev. 4/16 Prices and data subject to change without notice
IEC Manual Motor Starters
Section 6
Outline Drawings Outlines and Dimensions mm (in.) For Estimating Only
Non-metal Enclosure for GPS1BSAA-GPS1BSAP Surface Mounting with Emergency Push Button
Non-metal Enclosure for GPS1BSAA-GPS1BSAP Flush Mounting
Rev. 4/16 Prices and data subject to change without notice
www.geindustrial.com
Control Catalog
6-37
IEC Manual Motor Starters
Section 6
Outline Drawings Outlines and Dimensions mm (in.) For Estimating Only
Non-metal Enclosure for GPS1BSAA-GPS1BSAP Flush Mounting with Padlocking Device
Metal Enclosure for GPS1BH_ Starter, NEMA Type 1 (Drawing 55-216916)
6-38
Control Catalog
www.geindustrial.com
Rev. 4/16 Prices and data subject to change without notice
IEC Manual Motor Starters
Section 6
Outline Drawings Outlines and Dimensions mm (in.) For Estimating Only
Metal Enclosure for GPS2BH_ Starter, NEMA Type 1 (Drawing 55-216917)
Metal Enclosure for GPS1BH_/GPS2BH_ Starter, NEMA Type 3R/12 (Drawing 55-216918)
Rev. 4/16 Prices and data subject to change without notice
www.geindustrial.com
Control Catalog
6-39
IEC Manual Motor Starters
Section 6
Outline Drawings Outlines and Dimensions mm (in.) For Estimating Only
Metal Enclosure for GPS1BH_/GPS2BH_ Combination Starter, NEMA Type 1 (Drawing 55-216919)
Metal Enclosure for GPS1BH_/GPS2BH_ Combination Starter, NEMA Type 3R/12 (Drawing 55-216920) Controller GPS1BH__/GPS2BH__ GPS1BH__
6-40
Contactor
“A”
All except CL04
33.5 (1.32)
CL04
38.4 (1.51)
Control Catalog
www.geindustrial.com
Rev. 4/16 Prices and data subject to change without notice
IEC Manual Motor Starters
Section 6
Outline Drawings Outlines and Dimensions mm (in.) For Estimating Only
Metal Enclosure for GPS1BH_/GPS2BH_ Reversing Combination Starter or Combination Starter with CPT, NEMA Type 1 (Drawing 55-216921)
Metal Enclosure for GPS1BH_/GPS2BH_ Reversing Combination Starter or Combination Starter with CPT, NEMA Type 3R/12 (Drawing 55-216922)
Rev. 4/16 Prices and data subject to change without notice
www.geindustrial.com
Control Catalog
6-41
IEC Manual Motor Starters
Section 6
Wiring Diagrams – Accessories
6-42
GPAC_ _FBA Front Mount Auxiliary Contact
GPAC_ _LRA Side Mount Alarm/Auxiliary Contact
GPAC_ _FRA Front Mount Alarm Contact
GPAE11LLA Side Mount Short Circuit Alarm
GPAC_ _LLA Side Mount Auxiliary Contact
GPASLRA_ _Side Mount Shunt Trip
Control Catalog
www.geindustrial.com
Rev. 4/16 Prices and data subject to change without notice
IEC Manual Motor Starters
Section 6
Wiring Diagrams – Accessories
GPAULRAA_Side Mount Undervoltage Release
Rev. 4/16 Prices and data subject to change without notice
www.geindustrial.com
GPAU20L_AA_Side Mount Undervoltage Release with 2 NO early make contacts
Control Catalog
6-43
IEC Manual Motor Starters
Section 6
Short Circuit Current Rating Rated Breaking Capacity Toggle Operation, Standard Interruption Product Number GPS1BSAA GPS1BSAB GPS1BSAC GPS1BSAD GPS1BSAE GPS1BSAF GPS1BSAG GPS1BSAH GPS1BSAJ GPS1BSAK GPS1BSAL GPS1BSAM GPS1BSAN GPS1BSAP GPS1BSAR
FLA Adjustment Range
kAIC @ 240V
kAIC @ 480V
kAIC @ 600V
Max. Fuse Size (A)
Max. C.B. Size (A)
kAIC @ 240VGroup Installation
kAIC @ 480VGroup Installation
kAIC @ 600VGroup Installation
0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4-6.3 6.3-10 9-13 11-16 14-20 19-25 24-32
100 100 100 100 100 100 100 100 100 100 100 65 65 65 65
50 50 50 50 50 50 50 50 22 22 22 22 22 22 22
10 10 10 10 10 10 10 10 10 10 10 10 10 10 10
0.75 1 1.5 2.5 4 6 10 16 25 40 50 60 80 100 125
15 15 15 15 15 15 15 15 25 40 50 60 80 100 125
100 100 100 100 100 100 100 100 100 100 100 65 65 65 65
65 65 65 65 65 65 65 65 65 65 65 50 50 50 50
25 25 25 25 25 25 25 25 25 25 25 18 18 18 10
Max Fuse or C.B.-Size (A) Minimum Group Installation Contactor Size 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500
CL00 or MC0 CL00 or MC0 CL00 or MC0 CL00 or MC0 CL00 or MC0 CL00 or MC0 CL00 or MC0 CL00 or MC0 CL00 or MC0 CL00 or MC0 CL00 CL01 CL02 CL25 CL04
Manual motor starters are suitable for use with C-2000 contactors in series with the starter, but contactor rating must not be exceeded.
Rotary Operation, High Interruption Product Number GPS1BHAA GPS1BHAB GPS1BHAC GPS1BHAD GPS1BHAE GPS1BHAF GPS1BHAG GPS1BHAH GPS1BHAJ GPS1BHAK GPS1BHAL GPS1BHAM GPS1BHAN GPS1BHAP GPS1BHAR GPS2BHAK GPS2BHAL GPS2BHAM GPS2BHAN GPS2BHAP GPS2BHAR GPS2BHAS GPS2BHAT GPS2BHAU
FLA Adjustment Range
kAIC @ 240V
kAIC @ 480V
kAIC @ 600V
Max. Fuse Size (A)
Max. C.B. Size (A)
0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4-6.3 6.3-10 9-13 11-16 14-20 19-25 24-32 6.3-10 9-13 11-16 14-20 19-25 24-32 28-40 35-50 45-63
100 100 100 100 100 100 100 100 100 100 100 65 65 65 65 65 65 65 65 65 65 65 65 65
50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50
10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10
0.75 1 1.5 2.5 4 6 10 16 25 40 50 60 80 100 125 40 50 60 80 100 125 150 200 250
15 15 15 15 15 15 15 15 25 40 50 60 80 100 125 40 50 60 80 100 125 150 200 250
kAIC @ 240V- kAIC @ 480VGroup Group Installation Installation 100 100 100 100 100 100 100 100 100 100 100 65 65 65 65 100 100 100 100 100 100 100 100 100
65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 35
kAIC @ 600VGroup Installation
Max Fuse or C.B. Size(A)-Group Installation
kAIC @ 277Y/480VCombination Starter
Minimum Contactor Size
25 25 25 25 25 25 25 25 25 25 25 25 25 25 10 25 25 25 25 25 25 10 10 10
500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 1500 1500 1500 1500 1500 1500 1500 1500 1500
50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50
CL00 or MC0 CL00 or MC0 CL00 or MC0 CL00 or MC0 CL00 or MC0 CL00 or MC0 CL00 or MC0 CL00 or MC0 CL00 or MC0 CL00 or MC1 CL00 CL01 CL02 CL25 CL04 CL00 CL00 CL01 CL02 CL02 CL04 CL06 CL06 CL07
When using manual starters in combination with starter applications, use short circuit reset/indicator accessory. For GPS1BH_ starters add GPAPTIE terminal accessory. Maximum voltage for combination control is 277/480. Manual motor starters are suitable for use with C-2000 contactors in series with the starter; contactor rating must not be exceeded. When used in a combination installation, the contactor is not self-protected. Link available for GPS2* for CL04 and larger contactors only.
6-44
Control Catalog
www.geindustrial.com
Rev. 4/16 Prices and data subject to change without notice
IEC Manual Motor Starters
Section 6
Type 2 Short Circuit Rating Individual Group and Combination Starters Type 2 Coordination Under short circuit conditions, the starter must not result in danger to persons or the installation. After short circuit, the starter shall be capable of further use. No damage to the overload relay or other parts shall occur, except that welding of the contactor contacts is permitted when they are easily separated (as by a screwdriver) without significant deformation. Minimum front electrical clearance is 1” with CL06 and CL07 contactors, 0.8” with all other contactors. [email protected] UL508E Investigation (Individual Group or Combination)* Starter Type GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS2 GPS2 GPS2 GPS2 GPS2 GPS2 GPS2 GPS2 GPS2
FLA Adjustment Range
Product Number
Minimum Contactor Size @ 100kA @ 240V Interrupt Level
Link @ 100kA @ 240V Interrupt Level
0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4-6.3 6.3-10 9-13 11-16 14-20 19-25 24-32 6.3-10 9-13 11-16 14-20 19-25 24-32 28-40 35-50 45-63
GPS1BHAA GPS1BHAB GPS1BHAC GPS1BHAD GPS1BHAE GPS1BHAF GPS1BHAG GPS1BHAH GPS1BHAJ GPS1BHAK GPS1BHAL GPS1BHAM GPS1BHAN GPS1BHAP GPS1BHAR GPS2BHAK GPS2BHAL GPS2BHAM GPS2BHAN GPS2BHAP GPS2BHAR GPS2BHAS GPS2BHAT GPS2BHAU
CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL00 CL01 CL02 CL04 CL04 CL04 CL04 CL04 CL04 CL04 CL04 CL45 CL06 CL06 CL07
GPF1L02* GPF1L02* GPF1L02* GPF1L02* GPF1L02* GPF1L02* GPF1L02* GPF1L02* GPF1L02* GPF1L02* GPF1L02* GPF1L02* GPF1L04* GPF1L04* GPF1L04* GPF2L04* GPF2L04* GPF2L04* GPF2L04* GPF2L04* GPF2L45* GPF2L07* GPF2L07* GPF2L07*
[email protected]/400V per IEC947 (Individual Group or Combination)* Starter Type GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS2 GPS2 GPS2 GPS2 GPS2 GPS2 GPS2 GPS2 GPS2
FLA Adjustment Range
Product Number
Minimum Contactor Size @ 50kA @ 380/400V Interrupt Level
Link @ 50kA @ 380/400V Interrupt Level
0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4-6.3 6.3-10 9-13 11-16 14-20 19-25 24-32 6.3-10 9-13 11-16 14-20 19-25 24-32 28-40 35-50 45-63
GPS1BHAA GPS1BHAB GPS1BHAC GPS1BHAD GPS1BHAE GPS1BHAF GPS1BHAG GPS1BHAH GPS1BHAJ GPS1BHAK GPS1BHAL GPS1BHAM GPS1BHAN GPS1BHAP GPS1BHAR GPS2BHAK GPS2BHAL GPS2BHAM GPS2BHAN GPS2BHAP GPS2BHAR GPS2BHAS GPS2BHAT GPS2BHAU
CL00 CL00 CL00 LC00 CL00 CL00 CL01 CL01 CL02 CL25 CL25 CL25 CL25 CLL25 CL25 CL04 CL04 CL04 CL04 CL04 CL04 CL45 CL06 CL07
GPF1L02* GPF1L02* GPF1L02* GPF1L02* GPF1L02* GPF1L02* GPF1L04* GPF1L04* GPF1L04* GPF1L25* GPF1L25* GPF1L25* GPF1L25* GPF1L25* GPF1L25* GPF2L04* GPF2L04* GPF2L04* GPF2L04* GPF2L04* GPF2L04* GPF2L45* GPF2L07* GPF2L07*
Rev. 4/16 Prices and data subject to change without notice
www.geindustrial.com
[email protected] UL508E Investigation (Individual Group or Combination)* Starter Type GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS2 GPS2 GPS2 GPS2 GPS2 GPS2 GPS2 GPS2 GPS2
FLA Adjustment Range
Product Number
Minimum Contactor Size @ 50kA @ 480V Interrupt Level
Link @ 50kA @ 480V Interrupt Level
0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4-6.3 6.3-10 9-13 11-16 14-20 19-25 24-32 6.3-10 9-13 11-16 14-20 19-25 24-32 28-40 35-50 45-63
GPS1BHAA GPS1BHAB GPS1BHAC GPS1BHAD GPS1BHAE GPS1BHAF GPS1BHAG GPS1BHAH GPS1BHAJ GPS1BHAK GPS1BHAL GPS1BHAM GPS1BHAN GPS1BHAP GPS1BHAR GPS2BHAK GPS2BHAL GPS2BHAM GPS2BHAN GPS2BHAP GPS2BHAR GPS2BHAS GPS2BHAT GPS2BHAU
CL01 CL01 CL01 CL01 CL01 CL01 CL25 CL25 CL25 CL25 CL25 CL25 CL25 CL04 CL04 (35kA) CL04 CL04 CL04 CL04 CL04 CL45 CL06 CL06 CL07
GPF1L02* GPF1L02* GPF1L02* GPF1L02* GPF1L02* GPF1L02* GPF1L25* GPF1L25* GPF1L25* GPF1L25* GPF1L25* GPF1L25* GPF1L25* GPF1L04* GPF1L04* GPF2L04* GPF2L04* GPF2L04* GPF2L04* GPF2L04* GPF2L45* GPF2L07* GPF2L07* GPF2L07*
25kA (or as noted) @600V UL508E Investigation (Individual Group or Combination)* Starter Type GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS1 GPS2 GPS2 GPS2 GPS2 GPS2 GPS2 GPS2 GPS2 GPS2
FLA Adjustment Range
Product Number
Minimum Contactor Size @ 25kA @ 600V Interrupt Level
Link @ 25kA @ 600V Interrupt Level
0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.63 0.63-1.0 1-1.6 1.6-2.5 2.5-4 4-6.3 6.3-10 9-13 11-16 14-20 19-25 24-32 6.3-10 9-13 11-16 14-20 19-25 24-32 28-40 35-50 45-63
GPS1BHAA GPS1BHAB GPS1BHAC GPS1BHAD GPS1BHAE GPS1BHAF GPS1BHAG GPS1BHAH GPS1BHAJ GPS1BHAK GPS1BHAL GPS1BHAM GPS1BHAN GPS1BHAP GPS1BHAR GPS2BHAK GPS2BHAL GPS2BHAM GPS2BHAN GPS2BHAP GPS2BHAR GPS2BHAS GPS2BHAT GPS2BHAU
CL00 CL00 CL00 CL00 CL00 CL00 CL04 CL04 CL04 CL04 CL04 CL04 CL04 CL04 CL04 CL45 (5kA) CL45 (5kA) CL45 (5kA) CL45 (5kA) CL45 (5kA) CL45 (5kA) CL06 (10kA) CL06 (10kA) CL07 (10kA)
GPF1L02* GPF1L02* GPF1L02* GPF1L02* GPF1L02* GPF1L02* GPF1L04* GPF1L04* GPF1L04* GPF1L04* GPF1L04* GPF1L04* GPF1L04* GPF1L04* GPF1L04* GPF2L45* GPF2L45* GPF2L45* GPF2L45* GPF2L45* GPF2L45* GPF2L07* GPF2L07* GPF2L07*
*Maximum voltage for combination control 277/480. Minimum front electrical clearance is 1” with CL06 and CL07 contactors, and 0.8” with all other contactors.
Control Catalog
6-45
IEC Manual Motor Starters
Section 6
Specifications Starters
Frontal Auxiliary Blocks GPS1
Protection Thermal and Magnetic Maximum Rated Current Imax 32A Maximum Rated Operational Current Ie 32A Maximum Rated HP @ 460V 20 Hp Maximum Rated kW @ 400V 15 kW Power Loss 0.16-25A: 7 W 32A: 8.5 W Width Height Depth
45 mm 90 mm 75 mm (GPS1BS*)/ 92.5 mm (GPS1BH*) No. of Poles 3 Operation Toggle (GPS1BS*)/ Rotary (GPS1BH*) Mounting Position Turning to Front 30° Mounting Position Turning to Back 90° Mounting Position Turning to Side 180° DIN Rail Mounting Yes Mounting Screws 2 M4 (#6 screws) with Optional Mounting Tab Operation Altitude Up to 2000 Meters (6500 Feet) Storage Temperature –40 to +80° C (–40 to 176° F) Operation Temperature
–20 to +60° C (–4 to 140° F)
Temperature Compensation
–20 to +60° C (–4 to 140° F)
Rated Insulation Voltage Ui 690V Rated Operation Voltage Ue 690V Rated Voltage UL, cUL 600V Rated Frequency 50/60 Rated Impulse Withstand Strength Uimp 8KV Utilization Category IEC 60947-4-1 AC3 Overload Trip Class IEC 60947-4-1 10 Number of Current Ranges 15 Magnetic Release Ie Max Setting 13X Shock Resistance to IEC60068-2-25 30 g (width 20 ms) Vibration Resist., 50-150 Hz (X,Y,Z axis) 5G Std DIN Rail Mtg Vib. Res., 50-150 Hz (X,Y,Z axis) 8G DIN Rail Vib. Clamps Protection Degree (per IEC529) IP20 Safe from Finger Touch
GPS2 Thermal and Magnetic 63A 63A 40 hp 30kW 6.3-32A: 11W 40-50A: 15W 63A: 17W 55 mm 120 mm 107.5 mm 3 Rotary 30° 90° 180° Yes Yes Up to 2000m (6500 ft) –40 to +80° C (–40 to 176° F) –20 to +60° C (–4 to 140° F) –20 to +60° C (–4 to 140° F) 690V 690V 600V 50/60 8KV AC3 10 9 13X 30 g (width 20 ms) Contact factory Contact factory IP20 Safe from Finger Touch 50,000 ops 25,000 ops 25
Mechanical Performance 100,000 ops (70,000 for 32 Amp) Electrical Performance 100,000 ops (70,000 for 32 Amp) Max. Operation per Hour 25 (Motor Start Up) Phase Failure Protection Yes Yes Trip Test Function Yes Yes Trip Indication Yes Yes Terminal Type Pozidrive 2/Slotted Comb. Pozidrive 2/Slotted Comb. Max. Size Wire 1 Conductor w/o End Sleeve, solid or stranded 1-10 mm2/18-8 AWG 1-25 mm2/18-2 AWG stranded 2 Conductor w/o End Sleeve, solid or stranded 1-6 mm2/18-10 AWG 1-25 mm2/18-4 AWG stranded 1 Conductor w/ End Sleeve, stranded 1-6 mm2 stranded 1-16 mm2 2 Conductor w/ End Sleeve, stranded 1-6 mm2 stranded 1-16 mm2 Torque 2.0 Nm/18 lb. in. 4.0 Nm/36 lb. in. Standards IEC 60947-1, 60947-2, 60947-4 Yes Yes Din VDE66OT 100/101/102 Yes Yes UL 508/CSA 22.2 Yes Yes Marking CE Yes Yes Approvals UL, cUL listed Yes Yes Shipping Approvals On Request On Request PTB Test On Request On Request
6-46
Control Catalog
UL Contact Rating per NEMA ICS3-125 Continuous Ampere Rating Rated Operation AC Voltage Ue Rated Operational AC Current Ie AC Utilization Category Rated Operation DC Voltage Ue Rated Operational DC Current Ie DC Utilization Category Terminal Type Max. Size Wire (75°C Cu wire only) 2 conductor Torque
B300, Q300 5 115V, 230V 1.5A AC15 48V, 110V, 220V 1.38A, 0.55A, 0.27A DC13 Pozidrive2/Slotted Comb. 0.5-2.5 mm2/18-14 AWG 0.8Nm/7 lb. in.
Frontal Mount with 1NO or 1NC Contact; Frontal Mount Alarm with 1NO or 1NC Contact.
Lateral Auxiliary Blocks UL Contact Rating per NEMA ICS3-125 Rated Operation AC Voltage Ue Rated Operational AC Current Ie AC Utilization Category Rated Operation DC Voltage Ue Rated Operational DC Current Ie DC Utilization Category Terminal Type Max. Size Wire (75°C Cu wire only) 2 conductor Torque Width
A600, P300 125V, 230V, 400V, 500V, 690V 4A, 4A, 2.2A, 0.5A, 0.6A AC15 48V, 110V, 220V 5A, 1.3A, 0.5A DC13 Pozidrive2/Slotted Comb. 0.5-2.5 mm2/18-14 AWG 0.8Nm/7 lb. in. Adds 9 mm
Lateral Mount Auxiliary with 2NO, 1NO+1NC or 2NC contacts; Lateral Mount Alarm/Auxiliary with 1NO+1NO, 1NO+1NC, 1NC+1NO, 1NC+1NC; Short Circuit Signal Contact 1NO+1NC (SPDT)
Shunt Trip Power Consumption Pick-up (va/watts) Power Consumption Tripping Voltage Max. Operation Supply Power Consumption Pick-Up Voltage Max. Size Wire (75°C Cu wire only) 2 conductor Torque Width
21/12 0.7-1.1 Ve 5 ms for DC coil 0.85 - 1.1 Ve 0.5-2.5 mm2/18-14 AWG 0.8Nm/7 lb. in. Adds 18 mm
Undervoltage Release Power Consumption Pick-up (va/watts) Power Consumption Holding (va/watts) Power Consumption Tripping Voltage Power Consumption Pick-Up Voltage Torque Max. Size Wire (75°C Cu wire only) 2 conductor Width
www.geindustrial.com
21/12 8/1.2 0.35-0.7 Ve 0.85-1.1 Ve 0.8Nm/7 lb. in. 0.5-2.5 mm2/18-14 AWG Adds 18 mm
Rev. 4/16 Prices and data subject to change without notice
IEC Manual Motor Starters
Section 6
Time Current Curves
GPS1
The thermal release trip current curve applies to cold state. For single phase and DC loads the three phase must be connected in series. The magnetic release is based on the rated current In, which is the maximum value of the setting range of the manual motor starter. If the current is set to a lower value, the tripping current is increased by a corresponding factor. The short circuit release is set at the factory to a value equivalent to 13 times the rated current of the manual motor starter.
Rev. 4/16 Prices and data subject to change without notice
www.geindustrial.com
Control Catalog
6-47
IEC Manual Motor Starters
Section 6
Time Current Curves
GPS2
The thermal release trip current curve applies to cold state. For single phase and DC loads the three phase must be connected in series. The magnetic release is based on the rated current In, which is the maximum value of the setting range of the manual motor starter. If the current is set to a lower value, the tripping current is increased by a corresponding factor. The short circuit release is set at the factory to a value equivalent to 13 times the rated current of the manual motor starter.
6-48
Control Catalog
www.geindustrial.com
Rev. 4/16 Prices and data subject to change without notice